4.4 ELECTRICAL REQUIREMENTS
SEE FIGURES 3-1 THRU 3-8 ON THE FOLLOWING PAGES.
⌦
CAUTION: TO PREVENT DAMAGE TO THE MACHINE AND DANGER TO THE
OPERATOR, ALL ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED
ELECTRICIAN. THIS MACHINE OPERATES WITH LIQUID COOLANT AND MUST BE
GROUNDED IN ACCORDANCE WITH NATIONAL ELECTRIC CODES.
All three phase motors are dual speed and will operate on one voltage only. Single phase motors are
available in the 60 RPM speed, only. If the machine is not the same voltage as your plant voltage, you
will have to replace the motor and rewire the transformer and coolant pump. To insure satisfactory
performance, the supply voltage should be (+ or -) 10% of the motor voltage rating. Check the motor
data tag for full load current requirements. On machines equipped with the variable speed drive, the
drive can be used as a phase converter.
THE ELECTRICAL DIAGRAMS FOR THIS MACHINE ARE ON PAGES 12 THRU 18, FIGURES 3-1
THRU 3-8. For supply lines ten feet (303 cm) or shorter, we recommend 12 gauge wire. For lines longer
than ten (303 cm), we recommend 10 gauge wire. We do not recommend supply lines over twenty feet
(606cm) in length.
CPO-275-LT. (30-60 RPM)
MOTOR VOLTAGE
FULL LOAD CURRENT
HORSEPOWER
HI
LOW
HI
LOW
208
4.9
4.7
1.5
.75
230
4.7
4.5
1.5
.75
460
2.6
2.5
1.5
.75
230 1/Phase
9.4
1.5
CPO-275-HT. (60-120 RPM)
MOTOR VOLTAGE
FULL LOAD CURRENT
HORSEPOWER
HI
LOW
HI
LOW
208
7.9
5.7
2
1.6
230
7.7
5.5
2
1.6
460
4
2.9
2
1.6
230 1/phase
9.4
1.5
Summary of Contents for CPO-275
Page 8: ...Page 7 FIGURE 1...
Page 10: ...Page 9 FIGURE 2...
Page 13: ...Page 12 MANUAL OR PK W TRIGGER SWITCH FIGURE 3 1...
Page 14: ...Page 13 PKPD W EMERGENCY STOP FIGURE 3 2...
Page 15: ...Page 14 1 PHASE MOTOR W TRIGGER SWITCH FIGURE 3 3...
Page 16: ...Page 15 1 PHASE MOTOR W E STOP SERIAL S B3431 UP FIGURE 3 4...
Page 22: ...Page 21 FIGURE 5A...
Page 28: ...Page 27 FIGURE 8 FIGURE 9...
Page 30: ...Page 29 FIGURE 10...
Page 36: ...FIGURE 14 Page 35 C A B D...
Page 38: ...Page 37 FIGURE 15...
Page 40: ...Page 39 FIGURE 16...
Page 42: ...Page 41 FIGURE 17...
Page 44: ...Page 43 FIGURE 18...
Page 46: ...Page 45 FIGURE 19...
Page 48: ...Page 47 FIGURE 20...
Page 50: ...Page 49 FIGURE 20A...
Page 58: ...Page 57 FIGURE 23...
Page 60: ...FIGURE 24 Page 59...
Page 62: ...Page 61 G 078000 60 RPM 230 Volt 1 Phase T S 078001 60 RPM 230 Volt 1 Phase E S FIGURE 25...
Page 66: ...Page 65 FIGURE 27...
Page 68: ...Page 67 FIGURE 28...
Page 70: ...Page 69 FIGURE 29...
Page 74: ...Page 73 FIGURE 31...
Page 76: ...Page 75 FIGURE 32...
Page 78: ...Page 77 FIGURE 33...
Page 80: ...FIGURE 34 Page 79...
Page 82: ...Page 81 FIGURE 35...
Page 84: ...Page 83 FIGURE 36...
Page 86: ...Page 85 FIGURE 37...
Page 88: ...Page 87 FIGURE 38...
Page 90: ...Page 89 FIGURE 39...