Page 62
8.3 CONTROL VALVE INSPECTION
THE MACHINE WILL ONLY TRAVEL IN ONE DIRECTION.
THIS COULD BE CAUSED BY:
A.
Contamination in the hydraulic oil which causes the spool to stick in one position. With the
machine’s power off, the spool of the valve can be manually shifted. On each end of the control
valve, there is a pin in the center of the knurled nut that holds the coil on. To shift the spool
manually, use a small punch or similar device to push these pins in by hand, first one and then, the
other.
Turn the machine on and try it again. If the machine now operates, the hydraulic oil and the filter
should be changed.
B.
A defective coil on the control valve: The coils can be checked by using an Ohm meter. The wires
to the coils must be disconnected. If the ohm reading shows open, the coil is defective and must be
replaced.