FIGURE 7
Page 16
Once the hydraulic unit is mounted, the hoses must be attached.
On top of the cylinder there are (2) threaded holes. The centered hole is for the large diameter (18mm)
hose from the reservoir. The other hole is for the small diameter (5mm) pressure gauge hose.
Make sure there are no sharp bends in the hoses between the clamps and connections to the hydraulic
unit as shown below.
3.8 CONNECTING HYDRAULIC HOSES
MAKE SURE ALL HOSES ARE TIGHTENED SECURELY AND CONNECTED IN THE
CORRECT LOCATION BEFORE FILLING RESERVOIR AND OPERATING THE PRESS
FRONT
BACK
A
C
HANDLE AND
SCREW REMOVED
HANDLE INSTALLED IN
CORRECT ORIENTATION
PLACE HOSE MOUNTS ON
SAME SIDE AS POWER UNIT
(SHOWN ON RIGHT SIDE HERE)
IF 2 SPEED HANDLE IS IN AN UNDESIRABLE
POSITION REMOVE HEX HEAD SCREW AND
HANDLE, THEN REASSEMBLE IN CORRECT
ORIENTATION. (MAKE SURE HANDLE CAN
MOVE FROM HIGH SPEED TO LOW SPEED)
PRESSURE GAUGE GOES
IN THE HOLE THAT IS
NOT IN THE CENTER
90° FITTING GOES IN HOLE
CENTERED IN CYLINDER
TOP HOSE GOES TO
FRONT FITTING ON
THE POWER UNIT
BOTTOM HOSE GOES TO
THE BACK FITTING ON
THE POWER UNIT