5.2 CONNECTION TO THE ELECTRIC SYSTEM

Ensure that the power supply voltage corresponds to the voltage on the data plate of the machine. 

Connect the cable (4 x 1.5 sleeve) to the electric system, using a plug that is appropriate for the

characteristics of the same, thereby respecting color codes.

After the machine has been connected, verify that the rotation of the hydraulic power pack motor 

agrees with the direction indicated by the arrow shown on the same. If the motor rotation is not 

correct, reverse the two phase connections of the line and then, check again.

The pneumatic connection must be made to the supply system using a connector that is appropriate for 

the connector on the machine. Adjust the pressure at the filtering group.

5.3 INSTALLING THE BAND SAW BLADE

In order to install the band saw blade:

Lift the frame guard and remove the blade guide guards.

Loosen the tension adjuster.

Put on the band saw blade, sending it through the interior of the guides.

Re-tighten the tension adjuster. 

Put on all of the guards.

Turn the saw manually and use a brush to lubricate in between the two guides, using SAE 30 

lubricating oil.

ATTENTION: When replacing the band saw blade, always use protective gloves.

DANGER: After changing the band saw blade, put on all guards again. It is absolutely prohibited to 

work with them removed.

Summary of Contents for SU-280

Page 1: ...Page 1 MODEL SU 280 BAND SAW PRINTED JULY 2013...

Page 2: ...Connection to the Electric System 7 5 3 Installing the Band Saw Blade 7 5 4 Cutting Coolant 8 6 INSTRUCTIONS FOR USE 8 6 1 Proper and Improper Use 8 6 2 Function of the Operating Mechanisms 8 6 3 Rai...

Page 3: ...vent contact with hazardous areas of the machine EN 60204 1 Electrical equipment of industrial machines EN 13850 Machine safety emergency stop equipment 2006 42 CEE on Machine Safety 93 68 CEE on the...

Page 4: ...well as the name of the part and the code that appear in the last chapter of exploded views 3 0 TECHNICAL DATA MAIN MOTOR POWER TRIF 2 VEL MONOF 1 5 HP MOTOR SPEED3000 1500 RPM 3 000 1 500 RPM 1 500 R...

Page 5: ...Page 5 3 2 SELECTION OF THE BAND SAW...

Page 6: ...ic CAUTION Do not improperly dispose of the packaging Send the materials to be recycled or eliminated in accordance with current legislation 5 0 INSTRUCTIONS FOR ANCHORING SERVICE START UP 5 1 ANCHORI...

Page 7: ...gain The pneumatic connection must be made to the supply system using a connector that is appropriate for the connector on the machine Adjust the pressure at the filtering group 5 3 INSTALLING THE BAN...

Page 8: ...fe of the saw 6 0 INSTRUCTIONS FOR USE 6 1 PROPER AND IMPROPER USE Band saw machine for cutting all kinds of ferrous and non ferrous materials Use of the machine for cutting other materials is prohibi...

Page 9: ...n the arc bolt to adjust the height WARNING When performing the cut it is important that the saw should be lowered at a constant rate with no sharp changes of speed If the saw becomes jammed in the ma...

Page 10: ...on of the blade guide plates Guide adjustment See Section 7 1 Excessive wear on blade Tension too low or too high See Section 5 3 Guide plates worn Excessive pressure from upper plate See Section 7 1...

Page 11: ...cutting blade resulting in a widening at the upper edge To prevent this loosen the screws 6 and slightly raise the blade guide 7 The guide must be positioned so that after rotating the saw when it is...

Page 12: ...e It is mandatory to use officially approved work clothing which must be fastened Before starting work the operator must be sure to remove all tools and wrenches that have been used for any maintenanc...

Page 13: ...e keys must be placed under the care of qualified personnel Before taking any repairs on electrical devices disconnect the plug from the power supply In the event that extension cords are used ensure...

Page 14: ...hanged quickly from one length to another It has a 10 extension arm that can be used to cut short lengths closer to the blade The whole stop assembly can be flipped up out of the way if needed The Mul...

Page 15: ...ions or switchtometricmode Adjustablestop Flipstop canbeflippedup awayfromtabletobackfeed Portablepowerhead quicklydetachesfromrail List storage Holds10listswithupto10moveseach Quickandeasycalibration...

Page 16: ...Page 16 11 0 DRAWINGS SCHEMATICS 11 1 ELECTRICAL SCHEMATIC...

Page 17: ...Page 17...

Page 18: ...Page 18 11 2 MACHINE EXPLODED VIEW...

Page 19: ...Page 19 11 3 HYDRAULIC DESCENT EXPLODED VIEW...

Page 20: ...Page 20...

Page 21: ...Page 21 11 4 CLAMP EXPLODED VIEW...

Page 22: ...Page 22 11 5 GUIDES EXPLODED VIEW...

Reviews: