Page 12
4.7 Pneumatic Oil
Both the oleo-pneumatic converters and the filter group lubricator must be filled with ISO VG 16
VISCOSITY PNEUMATIC OIL or AW 32, 10 weight hydraulic oil. If none is available, use
hydraulic oil 16. This machine holds approximately (1) quart.
4.6 PRIMING/ADJUSTING THE COOLANT MISTER
The following procedure explains how to adjust the coolant mister or prime the system if it
has run out of coolant. This job requires 2 people in order to safely perform. Make sure to
adhere to the following instructions. Failure to do so may result in serious injury.
1.
Make sure the saw is clear of material, and the blade has been turned off.
2.
Fill the coolant reservoir located on the left side of the machine with coolant.
3.
Turn the 2-position switch for the clamps so that they are in "clamp mode".
4.
Turn the 2-position switch for the hood to the down position. The clamps must be engaged
and the saw hood down for the saw to cycle.
5.
Turn the feed rate control knob on the machine clockwise until it is turned off. This will
prevent the blade from raising.
6.
Disengage the safety switch on the left-hand blade door by turning the knob clockwise.
Once fully disengaged the door will be able to be opened.
7.
Before proceeding have a second person press and hold both green buttons on the control
panel briefly to engage saw. This should cause the solenoid to activate as though the the
blade is trying to raise and make a cut. With the blade door open, THE BLADE WILL
NOT SPIN. With the feed rate off, the blade will also not be able to raise out of the base
cabinet. If the solenoid does not activate, check to make sure that the clamps are engaged,
the hood is down, and the safety switch for the hood is functioning.
8.
If the saw solenoid activates and the blade remains down, the coolant mister can now be
adjusted/primed. The knob is located on the backside of the blade.
a. Adjust - Have the second person now press and hold the green buttons to activate the
the saw solenoid. As the buttons are held, the machine will begin to spray coolant onto
the blade. Adjust the spray to a satisfactory setting.
b. Prime - Fully open the mister knob. Have the second person now press and hold the
green buttons to activate the saw solenoid. As the buttons are held, the machine should
begin to purge the air out of the coolant system and then slowly turn to a heavy mist of
coolant. Adjust the spray to a satisfactory setting.
9.
Close the door and reset the safety switch by turning the knob counter-clockwise until tight.
Summary of Contents for SUP-600-NF
Page 1: ...You have downloaded a manual for our MODEL SUP 600 NF PRECISION MITER UP CUT NON FERROUS SAW...
Page 3: ...www scotchman com SUP 600 NF SAW FIGURE 1 Page 2...
Page 9: ...2 4 Cutting Capacity FIGURE 3 Page 7...
Page 16: ...FIGURE 8 1 2 3 4 5 6 7 9 10 14 13 12 11 Page 14 8 15...
Page 20: ...FIGURE 10 Filter Regulator Lubricator has a 1 4 BSPT Thread Page 18...
Page 26: ...Page 24 FIGURE 13 19 P N 677 LEGEND PLATE 1...
Page 40: ...Page 38 FIGURE 20 14 13 12 11 10 9 8 7 6 15 1 2 5 4 3...
Page 44: ...Page 42 FIGURE 23...