8.3 DIGITAL ANGLE DISPLAY (PART # 1554)
SETTING AN ELGO DIGITAL READOUT TO READ 90 DEGREES:
Turn the saw head to 90 degrees.
Press and hold the "F" key until the screen reads "P 01".
Press the "F" key until the screen reads "P 09".
Press the "F" key one more time so the screen will read "00000.00".
Press the "Set" key three times so the tens number is flashing.
Press the "Incr/Abs" key until the screen reads "00090.00".
Press and hold the "F" key for 3 seconds until the screen reads an angle.
Press and hold both the "F" key and the "Set" key until the screen reads 90.00° .
NOTE: This is a battery operated readout. When the battery goes dead, or is removed, the screen
will go blank. Or, when the battery is replaced, the readout will default to its original setting. If it
was programmed, like above to 90 degrees, you will simply need to set the saw at 90 degrees. Press
the "F" key and the "Set" key and it will re-set to 90 degrees.