Discharge temperature sensor.
•
Thermistor attached to the discharge line near the compressor. Reported temperature used by the
controller to determine end-of-cycle-fan-off-delay time. If discharge temperature exceeds a preset
maximum, controller will shut the machine off.
Note: Controller will operate machine in a default mode with thermistors disconnected from the
controller. Diagnostic code #5 or 7 will be displayed during that time.
Component Indicator Light Table
System
Indicator Light ON
Condenser Fan or Liquid Line Valve
LLV open
Water Pump
Pump Motor Powered
Purge Valve
Purge Valve Opens
Inlet Water Solenoid Valve
Inlet Water Valve Opens
Hot Gas
Hot Gas Valve Opens
Compressor Contactor
Contactor Closes
Ready to Harvest
Water contacting ice thickness sensor probe
Sump Empty
Open between mid sensor and common
Sump Full
Closed between top probe and mid probe
Curtain Switch
Curtain open
November 2010
Page 10
C2648 Service Manual
Electrical Component Details
Component Indicator Lights