Additional Maintenance
To Properly Place the Evaporator Covers
Removal:
1. Remove front panel.
2. Push up on evaporator cover and swing out the
base.
3. Use the finger holes to pull the lower inside
cover down and swing it out from the machine.
4. Pull upper inside cover out from behind the
pump hose.
Note: ALL COVERS MUST BE PROPERLY IN
PLACE or the MACHINE WILL MALFUNCTION.
Replacement:
1. Return upper inside cover to its original position.
2. Using finger holes to control the part, insert the
two tabs on the bottom of the lower inside cover
into the 5th slot of each cube deflector.
3. Push down and insert upper edge of the lower
inside cover into the slot on the bottom of the
evaporator bracket.
4. Insert evaporator cover into plastic slot at the
top of the compartment and then place the lower
end onto the reservoir wall.
To drain reservoir (if desired):
1. Remove front panel.
2. Push and hold the Off button until the machine
shuts off.
3. Push and hold the Clean button for 3 seconds.
The water pump will discharge water out the open
purge valve.
4. When the reservoir is empty release the Clean
button and push and release the Off button.
5. Push and release Freeze button to restart.
6. Return the front panel to its original position.
To Sanitize the Ice Storage Bin
1. Remove all ice.
2. Remove baffle.
3. Switch ice machine OFF or wait for it to be in a
cleaning cycle.
4. Mix a 1 gallon solution of warm (95-115oF.)
water and sanitizer. Follow local codes for
sanitizer.
5. Wash or spray the entire interior of the ice
storage bin with the sanitizer solution. This
includes the bottom of the ice machine and the
inside of the door, the door gaskets (if any) and
door frame.
6. Pour excess sanitizer into the bin to flush the
drain system.
7. If the approved sanitizer requires a rinse, rinse
all interior surfaces with potable water.
CME1856W
November 2001
Page 25
Insert Bottom Tabs in 5th
Slot of Cube Deflectors
Or: Drain the Reservoir by Holding Purge
Valve Open While in a Clean Cycle
Push and Hold
the Clean
Button for 3
Seconds to
Activate Purge
Valve