Water and Drain
Note: External drain tubing must be supported to
insure that it does not move and kink the internal
rubber tube.
Water Supply
: Connect a supply of cold, potable
water to the 3/8” fitting on the right side of the
cabinet. A male flare fitting is on the unit.
Note: This is an NSF listed ice machine and
contains provisions for back-flow prevention in its
design. No external back flow preventer is
required.
Drain:
Connect rigid drain tubing to the reservoir
drain fitting on the right side of the cabinet. Route
the drain either out the back or to the left side.
Run the drain tubing to the building drain. Do not
“Tee” into any other drain, including the bin or
dispenser drain.
Eclipse
ä
2000
September 2003
Page 22
Back View, Drain Tubing Installed for Back Drain
Potable
Water Inlet
Removable Plate
Purge Valve
Reservoir
Drain