Operational Characteristics:
CME656
Cycle Times (minutes):
System Pressures (PSIG):
Refrigerant Charge, R-404A
•
Air cooled: 36 ounces
•
Water cooled: 26 ounces
Typical Compressor Amps
•
Freeze: single phase = 6.5 - 8;
three phase = 4.5 - 5
•
Harvest: single phase = 9 - 10; three phase
= 5.5 - 6
Typical Harvest Ice Weight
•
6.5 - 7 lb.
Water Cooled:
•
Discharge Pressure: 245 PSIG
•
Hi Pressure Cuts Out at: 450 PSIG
Fan Control Switch - for units so equipped:
•
Cut In: 240 PSIG + - 20 PSIG
•
Cut Out: 190 PSIG + - 10 PSIG
CME256, 506, 656, 806: AutoIQ™ Cubers
January 2002
Page 29
Air Cooled
70
o
F. indoor air, 50
o
F. water
90
o
F. indoor air, 70
o
F. water
Freeze
14 - 15
15 - 16
Harvest
1:30
1:30
Water Cooled
70
o
F. indoor air, 50
o
F. water
90
o
F. indoor air, 70
o
F. water
Freeze
15 - 16
16 - 17
Harvest
3
2
Air Cooled
70
o
F. indoor air, 50
o
F. water
90
o
F. indoor air, 70
o
F. water
Suction: End of Freeze
25 - 27
24 - 26
Suction: Peak in Harvest
83 - 87
84 - 88
Discharge: 5 minutes into Freeze
215 - 225
290 - 300
Discharge: Minimum in Harvest
195 - 205
210 - 220
Water Cooled
70
o
F. indoor air, 50
o
F. water
90
o
F. indoor air, 70
o
F. water
Suction: End of Freeze
24 - 26
24 - 26
Suction: Peak in Harvest
85 - 90
80 - 85
Discharge:
245 PSIG
245 PSIG
Discharge: Minimum in Harvest
180 - 190
190 - 200