Water Pump
1. Remove front panel.
2. Unplug water pump electrical connection.
3. Drain water reservoir.
4. Use corbin clamp pliers to loosen and slide
corbin clamps on hoses away from pump.
5. Remove screws retaining pump to bracket.
6. Pull pump out of ice machine.
7. Reverse to reassemble.
8. Replace front panel.
8. Reconnect electrical power.
Transducer
1. Disconnect electrical power BEFORE removing
transducer.
2. Remove front panel, and locate transducer near
the back of the cabinet.
3. Twist inner portion of transducer
counter-clockwise and pull up gently.
4. Unplug transducer and remove from the
machine.
5. Reverse steps 1-5 to reassemble.
Inlet Water Solenoid Valve Assembly
To remove the inlet water solenoid valve assembly:
1. Shut OFF water supply to machine.
2. Loosen and remove outlet water line from the
inlet water solenoid valve assembly.
3. Remove screws and pull the water solenoid
valve out to gain access.
4. Pull electrical cord from solenoid coil terminals.
5. Remove inlet water fitting from the water
solenoid valve. To replace the inlet water valve
assembly, reverse the removal procedures.
Bin Ice Level Control Circuit Board
1. Disconnect Electrical Power before removing
circuit board.
2. Remove front panel.
3. Remove control box cover.
4. Remove wires from circuit board connections.
5. Unlock circuit board fasteners by twisting 1/2
turn.
6. Pull circuit board of off fastener posts.
7. Reverse to reassemble, refer to wiring diagram
as needed.
REMOVAL AND REPLACEMENT
STRAINER
INLET WATER VALVE
Electrical Shock
Hazard.
Electrical shock can
cause personal injury.
Disconnect power before
begining to service
components
CMS1202
September 1993
Page 24