INITIAL START UP
1. Remove the front panels by removing screws at
the base and pulling out.
2. Remove two screws and the control box cover.
3. Check that the two switches on the control box,
the ICE-OFF-WASH rocker switch and the
COMPRESSOR ON-OFF toggle switch are in the
OFF position.
4. OPEN the water supply line shut off valve.
5. Switch the electrical power to the machine ON.
6. Inside the control box is the shaft of the timer
and the switch assembly. Rotate the shaft of the
timer until the actuator arm on the microswitch
drops off outer cam into cam slot. See “Front View
of Timer”.
7. Move the ICE-OFF-WASH rocker switch to the
ICE position.
8. Check the water fill cycle: For several minutes
the inlet water valve will be open and water will
flow into the reservoir. Near end of the fill cycle,
water should be overflowing the reservoir and
draining thru the reservoir drain. If at the end of the
fill cycle the reservoir is not full, repeat step 6.
Check that the sump covers are snapped in place.
Check that the water distributors are properly
seated at the top of the evaporators, and that
water is flowing over all of the cube cells.
Note: Some water may spray from the evaporators
is normal when the machine is new. The spray will
stop after a few batches of ice.
9. When the sump has filled, move the compressor
ON-OFF toggle switch, to the ON position.
10. On air cooled models the fan motors will begin
to blow warm air out the back of the machine.
Water cooled models will begin to flow warm water
out of the condenser drain.
Note: To optimize the balance between ice
production and water use, the freeze cycle
discharge pressure must be 220 P.S.I.G. Check
the discharge pressure and adjust the water
regulating valve to obtain 220 P.S.I.G. discharge.
11. Check operation of the freezing cycle: Ice will
begin to form from the top of the evaporators to the
bottom. After the first cycle freezing time will range
between 12 and 15 minutes. Longer time for
temperatures above 70
o
F. and shorter time
required when temperatures are below 70
o
F.
Average complete cycle time is about 16 minutes.
CUBE SIZE
CONTROL
TIMER
CONTROL BOX
ON/OFF/WASH SWITCH
ICE LEVEL CONTROL
FRONT VIEW OF TIMER
MICROSWITCH
ACTUATOR
BUTTON
CAM
HARVEST
PORTION
FREEZE
PORTION
CMS1402
September 1993
Page 8