Flow Chart - Freeze Mode Details
July 2007
Page 16
CS0415
Service Manual
Freeze Mode
Water Level
Sensor
Detected?
Comp., fan motor,
spray pump are on
Water level
drops below
sensor?
Comp., fan motor,
spray pump are on
for 25 minutes
maximum
Comp., fan motor,
spray pump are on
Yes
No
Harvest Mode
Hung Slab Noted
Yes
No
Water level
drops below
sensor?
Yes
20 minutes up?
No
Yes
No
5 minutes up?
Yes
No