Service Diagnosis
• No ice, compressor and fan are on, pump not
spraying water
– Check for water in reservoir
• Check drain plug for leaks
– Check for pump hose disconnected
– Check pump motor voltage. If none and blue Freeze
mode light is ON, wait 30 seconds. If still no voltage,
replace controller (pump relay failure)