background image

Initial Start Up

1.

Remove left front louver. Check machine for
any packing or wires rubbing moving parts.
Note location of control board at the left.

2.

Switch the on off
switch to On.

3.

Switch on the
electrical power
to the machine.
Observe that
some of the
control’s
indicator lights
glow and its
display shows

O

.

4.

Open the water
supply valve.

5.

Push and
release the ON button. The code display will
begin to blink

F

. Be sure front On/Off switch is

in the ON position.

The purge valve opens and the water pump starts.
In a few seconds the purge valve closes and the
water pump stops. Water will flow into the machine
until the reservoir is full. The hot gas valve and
harvest assist device will activate, then the
compressor and water pump will start. If it’s an air
cooled model the fan(s) motors will begin to turn a
few moments after the compressor starts. The
display will show a continuous

F

. Five seconds later

the hot gas valve will close and the harvest assist
device will return to its standby position. Warm air
will be discharged from air cooled models.

6.

Observe the Ready for Harvest indicator light.
It may blink early in the cycle, that is normal.
The control will ignore that signal for the first 6
minutes of freeze.

7.

During the Freeze cycle move the curtain and
observe that the SW1 or SW2 light on the
control board blinks On when the curtain
moves away from the evaporator and Off when
returned to its normal position.

Note: Moving the curtain during the Freeze cycle
has no affect on control function, but will cause
water to flow into the bin.

8.

When enough ice has frozen, the Ready for
Harvest indicator light will be on steady. After

it’s been on steady for a few seconds Harvest
will begin.

The display shows an

H.

The hot gas valve opens,

the air cooled fan motor(s) shut off and the harvest
assist mechanism is activated. The purge valve
opens to drain some water, when it does the float
valve opens to refill the reservoir. After a few
seconds the purge valve closes but the float valve
continues to fill the reservoir. Harvest continues
until the ice is released as a unit and forces the
curtain to open. When the curtain opens it signals
the controller which returns the unit to a freeze
cycle.

9.

Check the ice harvested for proper bridge
thickness. The ice bridge is factory set at 1/8
inch. If needed, adjust bridge thickness. Do
NOT make it too thin.

10. Return the louver to its normal position and

secure it to the machine.

11. Instruct the user in the operation of the

machine and its maintenance requirements.

12. Fill out and mail the warranty registration form.

Write the day, month and year of initial start up
here:

_______________________________________

Typical Ice Making Cycle Times (minutes).

Listed times are for clean machines in proper
installations. Cycle length at startup will be longer
until the system stabilizes.

Model

70

o

F air /

50

o

F. water

90

o

F. air /

70

o

F. water

CU1526A

22-25

36-29

CU1526W

21-24

28-31

CU2026A

15-18

25-28

CU2026W

15-18

20-23

CU3030A

12-15

19-22

CU3030W

10-13

15-18

May 2008

Page 10

CU1526, CU2026, CU3030
User Manual

Manual
Harvest

Clean

Code

Display

Component Operation Indicator Lights

Code

Description

. . . . . . . . . . Freeze Cycle

flashes . . . . Freeze Cycle is Pending

. . . . . . . . . . Harvest Cycle

flashes . . . . Manual Harvest

. . . . . . . . . . Bin is Full
. . . . . . . . . . Clean Cycle
. . . . . . . . . . Board Locked
. . . . . . . . . . Test Mode
. . . . . . . . . . Off
. . . . . . . . . . Self Test Failed

flashes. . . . Max Freeze - Retrying

. . . . . . . . . . . Max Freeze Time Shut Down

flashes . . . . Max Harvest - Retrying

. . . . . . . . . . Max Harvest Time Shut Down
. . . . . . . . . . Slow Water Fill
. . . . . . . . . . High Discharge Temp
. . . . . . . . . . Sump Temp Sensor Failure
. . . . . . . . . . Discharge Temp Sensor Failure

flashes . . . Short Freeze - Retrying

Short Freeze - Thin ice

- Unit Remotely

Locked Out - Contact Leasing Company

F
F
H
H
b
C
L
d
O
E
1
1
2
2
3
4
5
7
8
8 . . . . . . . . . . . .

All 4 Upper Lights Flashing

Control Operation - See Manual

Water Light On

De-Scale Light On

Flush Setting

Test Mode

Recall Diagnostic Codes

Reset from Code 1, 2, 4 or 8

- Restore water supply to

machine.

- Clean and sanitize

machine.

- To Change: Depress Off

for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.

- Depress Off for 3 seconds,

then depress Clean for 3 seconds.

- Depress Off

for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.

- Depress

Off then Depress On.

Technician Section

02-4302-01

On

Off

Power

Status

De-scale

Water

Sanitize

Summary of Contents for CU3030

Page 1: ...Installation and User s Manual for Self Contained Cubers Models CU1526 CU2026 and CU3030 ...

Page 2: ...Maintenance which provides the user with the information needed keep it operating efficiently Note any Caution or Warning symbols when they appear on the product or in this manual They indicate potential hazards May 2008 Page 1 CU1526 CU2026 CU3030 User Manual Table of Contents Installation Product Specifications Page 2 Model Number Description Page 3 Water Page 4 CU1526 and CU2026 Cabinet Layout ...

Page 3: ...capacity Environmental Limitations Minimum Maximum Air temperature 50o F 100o F Water temperature 40o F 100o F Water pressure 20 psi 80 psi Note Ice making capacity will be severely reduced for air cooled machines in hot environments such as those over 95 degrees Power supply acceptable voltage ranges Minimum Maximum 115 volt model 104 126 230 volt model 198 253 Warranty Information The warranty s...

Page 4: ... components not specifically approved by Scotsman Scotsman reserves the right to make design changes and or improvements at any time Specifications and design are subject to change without notice May 2008 Page 3 CU1526 CU2026 CU3030 User Manual Dimensions w x d x h without legs Model Electrical volts Hz phase Condenser Total Load Amps Maximum Fuse Size 26 62 x 27 5 x 33 CU1526SA 1 115 60 1 Air 7 7...

Page 5: ...veral models The model number on the product is located in two places on the back dataplate and on the model and serial number tag located behind the front panel See the illustration for the dataplate and serial tag locations Write the model and serial number of this product here ________________________________________ Water purge Cube ice machines use more water than what ends up in the bin as i...

Page 6: ...9 0 22 12 56 2 4 00 MINIMUM UTILITY CLEARANCE 10 2 6 00 15 2 22 25 56 5 29 65 75 3 27 5 69 9 4 86 12 3 26 62 67 6 30 04 76 3 15 55 39 5 2 60 6 6 4 85 12 3 6 50 16 5 3 19 8 1 4 32 11 5 92 15 DRAIN 3 4FPT CONDWATER REGULATOR 3 8NPT W CONLY CONDDRAIN 1 2NPT W CONLY POTABLE WATERINLET 3 8FLARE POWERCORD ...

Page 7: ... 95 65 9 4 69 11 9 30 0 76 2 30 62 77 8 4 00 MINIMUM UTILITY CLEARANCE 10 2 6 00 15 2 24 25 61 6 29 63 75 3 6 99 17 7 3 19 8 1 4 33 11 29 36 74 6 2 77 7 4 65 11 8 6 27 15 9 23 82 60 5 DRAIN 3 4FPT CONDWATER REGULATOR 3 8NPT W CONLY CONDDRAIN 1 2NPT W CONLY POTABLE WATERINLET 3 8FLARE POWERCORD ...

Page 8: ...ct electrical power 6 Remove door open about 1 5 and pull bottom out 7 Remove the top panel there are two fasteners under the front corners of the top Back them out and lift the top up push back slightly and lift panel up and off the machine 8 Disconnect the drain tube from the bin drain fitting 9 Remove two bolts from the bottom of the bin one on the left and one on the right 10 Remove bolt from ...

Page 9: ...nded Note This NSF listed model has a 1 anti back flow air gap between the float valve orifice and the highest possible reservoir water level no back flow device is required for the potable water inlet 2 Connect drain tubing to drain fittings 3 Route the drain tubing to building drain Follow local codes for air gap Drain Tubing Use rigid drain tubes and route them separately do not Tee into the bi...

Page 10: ...te the ice scoop if supplied and have it available for use when needed Final Check List 1 Is the unit located indoors in a controlled environment 2 Is the unit located where it can receive adequate cooling air 3 Has the correct electrical power been supplied to the machine 4 Have all the water supply connections been made 5 Have all the drain connections been made 6 Has the unit been leveled 7 Hav...

Page 11: ...es to fill the reservoir Harvest continues until the ice is released as a unit and forces the curtain to open When the curtain opens it signals the controller which returns the unit to a freeze cycle 9 Check the ice harvested for proper bridge thickness The ice bridge is factory set at 1 8 inch If needed adjust bridge thickness Do NOT make it too thin 10 Return the louver to its normal position an...

Page 12: ...g can be changed to one of 5 manual settings or left on automatic Setting Water Type 1 Minimum RO water or equivalent 2 Moderate Low TDS non RO 3 Standard for typical water 4 Heavy High TDS 5 Maximum Very high TDS A Automatic Factory setting To set purge 1 Switch the machine OFF by holding the Off button in until a number or the letter A shows on the display 2 Press and release the On button repea...

Page 13: ...ve been shut off or the water filter cartridges might need to be changed If the De Scale light is on the machine has determined that it needs to be cleaned Contact an authorized Scotsman service agent and have the machine cleaned de scaled and sanitized May 2008 Page 12 CU1526 CU2026 CU3030 User Manual Note A Component Indicator Light switches ON to indicate that the component is operating Note Th...

Page 14: ... large sections That ice will break up into random parts as it falls into the bin but some large sections may remain on top of the ice in the bin When removing ice tap the groups of ice with an ice scoop to separate them into smaller units Using the ice will help to level it out and allow the machine to fill it to its maximum level Heat Air cooled models will generate heat when in operation That h...

Page 15: ... 5 Push and release the Clean button The yellow Clean light will blink and the display will show C The machine will drain the reservoir and refill it Go onto the next step when the reservoir has filled 6 Pour 8 ounces of Scotsman Clear 1 ice machine scale remover into the reservoir 7 Allow the ice machine scale remover to circulate in the water system for at least 10 minutes 8 Push and release the...

Page 16: ... solution into the reservoir 21 Circulate the sanitizer solution for 10 minutes then push and release the Clean button 22 Allow the water system to be flushed of sanitizer for at least 20 minutes then push and release the Off button 23 Push and release the On button to resume ice making 24 Return the top panel and front louvered panel to their normal position and secure with the original fasteners...

Page 17: ...and release the On button To Shut the Machine Off Move the On Off switch to the Off position or at the controller Push and hold the Off button for 3 seconds or until the machine stops May 2008 Page 16 CU1526 CU2026 CU3030 User Manual Manual Harvest Clean Code Display Component Operation Indicator Lights Code Description Freeze Cycle flashes Freeze Cycle is Pending Harvest Cycle flashes Manual Harv...

Page 18: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 533 6006 www scotsman ice com 17 3234 01 ...