FOR THE INSTALLER: Specifications
The machine is designed to fit a variety of
Scotsman storage bins such as BH800 or SB480.
Installation Limitations:
The machine is designed
for indoor installations only.
Minimum
Maximum
Air Temp
50
o
F
100
o
F
Water Temp
40
o
F
100
o
F
Voltage
198 VAC
253 VAC
Water Pressure
20 psi
80 psi
RO Water Limitation: Water conductivity must be
no less than 35 microSiemens/cm.
SPECIFICATIONS:
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of U.L., N.S.F., and C.U.L.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Double System RL
January 2004
Page 2
15.53"
3.1"
SUCTION LINE CONNECTION
7
8
"
LIQUID LINE CONNECTION
1
2
"
20.84"
9.43"
5.25"
3"
17.8"
18.8"
21.66"
ELECTRICAL INLET
POTABLE WATER INLET 3/8" FLARE
DRAIN 3/4" FPT
BACK VIEW
Model
Cabinet Size
System Refrigerant
BTUH required*
Voltage
Ice Type
FME2404RL
42"w x 27"h x 24"d R-404A
12,000
208-230 Flake
NME1854RL
same
R-404A
12,000
208-230 Nugget
FM2402RL-C same
R-22
12,500
208-230 Flake
NM1852RL-C same
R-22
12,500
208-230 Nugget
FME3004RL
same
R-404A
15,000
208-230 Flake
NME2504RL
same
R-404A
15,000
208-230 Nugget
* Use to determine needed condensing unit capacity. Not an AC load.