Operation
Operation
-
-
Harvest Control
Harvest Control
•
Controller begins timing harvest
•
Ice falling interrupts the signal from the ice sensor
emitter to the receiver
– The time of that interrupt is recorded by the controller
– The last time the controller receives an interrupt signal
is saved as the cube release time
– Extra time is calculated from the actual cube release
time
Measured Cube Release Time + Calculated Extra Time =
Harvest Time