background image

SCOTSMAN ICE SYSTEMS

775 Corporate Woods Parkway, Vernon Hills, IL 60061

800-533-6006

www.scotsman-ice.com

17-3222-01

Summary of Contents for F0522

Page 1: ...Installation and User s Manual for Modular Flaked Nugget Ice Machines Models F0522 F0822 F1222 F1522 N0422 N0622 N0922 and N1322 Air Cooled Water Cooled and Remote Air Cooled ...

Page 2: ... F1222 N1322 F1522 Air Water or Remote User Manual Table of Contents Installation Page 2 Location Page 3 N0422 F0522 N0622 F0822 N0822 Cabinet Layout Page 4 N0922 F1222 N1322 F1522 Cabinet Layout Page 5 Unpacking Install Prep Page 6 Water Air or Water Cooled Page 7 Electrical All Models Page 8 Refrigeration Remote Condenser Models Page 9 Remote Condenser Location Limits Page 10 For The Installer R...

Page 3: ...ome filters have treatment in them for suspended solids Check with a water treatment service for a recommendation RO water This machine can be supplied with Reverse Osmosis water but the water conductivity must be no less than 10 microSiemens cm Potential for Airborne Contamination Installing an ice machine near a source of yeast or similar material can result in the need for more frequent sanitat...

Page 4: ... have the same footprint 22 inches wide by 24 inches deep Confirm available space when replacing a prior model Bin adapter list B222S or B322S no adapter needed B330P or B530P or B530S Use KBT27 B842S KBT39 B948S KBT38 for single unit B948S KBT38 2X for two units side by side BH1100 BH1300 and BH1600 upright bins include filler panels to accommodate a 22 inch wide ice machine No adapter is needed ...

Page 5: ... 4 2 17 5 5 1 59 4 2 63 6 7 14 55 37 19 31 49 17 55 44 6 3 33 8 5 15 40 39 1 WATERCOOLED BACKVIEW 3 8 FLARE MACHINE WATER INLET 3 4 FPT DRAIN 88DIA ELECTRICAL CONNECTION 3 8 FPT CONDENSER WATER INLET 1 2 FPT CONDENSER DRAIN 18 88 48 2 68 6 8 14 60 37 1 12 40 31 5 7 40 18 8 10 94 27 8 1 59 4 2 17 5 5 REMOTECOOLED BACKVIEW REMOTECOND LIQUIDLINE 3 8 MALECPLG REMOTECOND DISCHARGELINE 1 2 MALECPLG 88DI...

Page 6: ...7 6 8 18 59 47 2 1 59 4 19 80 50 3 18 05 45 8 3 37 8 6 15 44 39 2 WATERCOOLED BACKVIEW 88DIA ELECTRICAL ACCESS 3 8 FLARE MACHINE WATER INLET 3 4 FPT DRAIN 1 2 FPT CONDENSER DRAIN 13 39 34 2 67 6 8 18 59 47 2 1 59 4 2 17 5 5 7 39 18 8 10 93 27 8 21 84 55 5 REMOTECOOLED BACKVIEW 88DIA ELECTRICAL ACCESS 3 8 FLARE MACHINE WATER INLET 3 4 FPT DRAIN 3 8 FPT CONDENSER WATERINLET REMOTECOND LIQUIDLINE 3 8...

Page 7: ...up by changing the bezel in the front panel s trim strip A cover up bezel is included with the hardware bag Remove any packaging such as tape or foam blocks that may be near the gear reducer or ice chute Level the bin and ice machine front to back and left to right by using the bin leg levelers Panel Removal 1 Locate and loosen the two screws at the front edge of the top panel 2 Pull the front pan...

Page 8: ...alent is recommended Water filtration is recommended If there is an existing filter change the cartridge Connect the water cooled water supply to the condenser inlet Note Do NOT filter water to the water cooled condenser circuit Drains use rigid tubing Connect the drain tube to the condensate drain fitting Vent the drain Connect the water cooled condenser drain tube to the condenser outlet Do not ...

Page 9: ... 60 1 Air 15 2 20 N0422W 1 same 111 60 1 Water 14 4 20 F0522A 1 same 115 60 1 Air 15 2 20 F0522W 1 same 115 60 1 Water 14 4 20 N0622A 1 same 115 60 1 Air 18 3 25 N0622W 1 same 115 60 1 Water 16 7 25 N0622R 1 same 115 60 1 Remote 19 4 25 N0622A 32 same 208 230 60 1 Air 9 8 15 N0622W 32 same 208 230 60 1 Water 8 9 15 F0822A 1 same 115 60 1 Air 18 3 25 F0822W 1 same 115 60 1 Water 16 7 25 F0822R 1 sa...

Page 10: ...RC111 1 F1222R N0922R 208 230 ERC311 32 N1322R 208 230 ERC311 32 Do not reuse condenser coils contaminated with mineral oil used with R 502 for example They will cause compressor failure and will void the warranty A headmaster is required for all remote condenser systems Prior condensers did not have a headmaster New head prior condenser retrofits can use headmaster kit KPFHM Use of non Scotsman c...

Page 11: ...ive prior written authorization from Scotsman to maintain warranty Do NOT Route a line set that rises then falls then rises Route a line set that falls then rises then falls Calculation Example 1 The condenser is to be located 5 feet below the ice machine and then 20 feet away horizontally 5 feet x 6 6 33 33 20 53 This location would be acceptable Calculation Example 2 The condenser is to be locat...

Page 12: ...d to make and seal the hole in the roof for the line sets The suggested hole diameter is 2 inches Meet all applicable building codes Roof Attachment Install and attach the remote condenser to the roof of the building using the methods and practices of construction that conform to the local building codes including having a roofing contractor secure the condenser to the roof July 2009 Page 11 N0422...

Page 13: ...ctrical power supply to the condenser Caution Do NOT kink the refrigerant tubing while routing it 3 Route the refrigerant tubes thru the roof opening Follow straight line routing whenever possible Excess tubing may EITHER be coiled up INSIDE the building OR cut out prior to connection to the ice maker and condenser If the excess tubing is cut out after re brazing the tubing must be evacuated prior...

Page 14: ...ntil it bottoms out or a definite increase in resistance is felt It is important that ONLY the nut on the pre charged tube be turned or the diaphragms will be torn out by the piercing knives and they will be loose in the refrigeration system Note As the couplings are tightened the diaphragms in the quick connect couplings will begin to be pierced As that happens there will be some resistance to ti...

Page 15: ... the potable water fitting 3 8 OD copper tubing or the equivalent is recommended Water filtration is recommended If there is an existing filter change the cartridge Drains use rigid tubing Connect the drain tube to the condensate drain fitting Vent the drain Do not Tee ice machine drains into the drain tube from the ice storage bin or dispenser Back ups could contaminate and or melt the ice in the...

Page 16: ...pters been properly installed Control Operation Use and Operation Once started the ice machine will automatically make ice until the bin or dispenser is full of ice When ice level drops the ice machine will resume making ice Caution Do not place anything on top of the ice machine including the ice scoop Debris and moisture from objects on top of the machine can work their way into the cabinet and ...

Page 17: ...riod is 6 months of power up time Sanitizing Every time the scale is removed or as often as needed to maintain a sanitary unit Sensor Cleaning Every time the scale is removed Top bearing check At least twice a year or every time the scale is removed Maintenance Air filters 1 Pull air filter s from panel 2 Wash the dust and grease off the filter s 3 Return it them to their original position s Do no...

Page 18: ...sconnecting the leg of the hose connected to the water sensor and draining it into the bin or a bucket Return the hose to its original position Discard or melt all ice made during the previous step 13 To sanitize the water system mix a locally approved sanitizing solution An example of a sanitizing solution is mixing one ounce of liquid household bleach and two gallons of 95 115 degree F water 14 ...

Page 19: ... is white over time some gray will appear over the rollers that is normal Add grease to replace the gray grease or if gaps between rollers are visible If grease is watery all gray or rust is visible have the bearing replaced See the next page for more information Note When checking the top bearing always inspect the drip pan for water seal leaks If water is present in the drip pan service the wate...

Page 20: ...rtridge pn A36808 001 Be sure to inject grease evenly and thoroughly July 2009 Page 19 N0422 F0522 N0622 F0822 N0922 F1222 N1322 F1522 Air Water or Remote User Manual Needle pn 02 3559 01 Bearing Check Drip Pan For Water Drip Pan Change De Scale Notification Interval This feature is accessible only from standby Status Light Off 1 Press and hold Clean button for 3 seconds This starts the Time to Cl...

Page 21: ... position Note Eye holders must be mounted properly They snap into a centered position and are properly located when the wires are routed to the back and the left eye is the one with 2 wires at the connector The ice machine senses water by a probe located near the water reservoir At least twice a year the probe should be wiped clean of mineral build up 1 Shut off the water supply 2 Remove front pa...

Page 22: ...ob points to the arrow on the label Dispenser applications Nugget ice only Set the adjustment knob to either the first or second position CW after the maximum fill position Smart Board Optional Advanced Feature Board KSBU When this option is present there is an additional display panel in the area below the main control board It is not visible when the front panel is on The Advanced Feature Board ...

Page 23: ... the following 1 Has the water supply to the ice machine or building been shut off If yes the ice machine will automatically restart within minutes after water begins to flow to it 2 Has power been shut off to the ice machine If yes the ice machine will automatically restart when power is restored 3 Has someone shut the power off to the remote condenser while the ice machine still had power If yes...

Page 24: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 533 6006 www scotsman ice com 17 3222 01 ...

Reviews: