N0922L, N1322L, F1222L, F1522L
Remote Low Side Service Manual Includes Prodigy Plus
December 2014
Page 22
Check Top Bearing
This task should only be done by a qualified service
technician
The bearing in the breaker should be checked at least
two times per year.
Check the bearing by:
1. Removing the bail clamp and ice chute cover
2. Unscrewing the ice sweep
3. Removing the water shed & unscrewing the
breaker cover (left hand threads).
4. Inspect the top of the bearing. When new the
grease is white, over time some gray will appear
over the rollers, that is normal. Add grease to
replace gray grease or if gaps between rollers
are visible. If grease is watery, all gray or rust is
visible, have the bearing replaced. See the next
page for more information.
Note: When checking the top bearing, always inspect
the drip pan for water seal leaks. If water is present
in the drip pan, service the water seal and check the
gear reducer's lubricant. See the next page.
Bail Clamp