background image

N0922L, N1322L, F1222L, F1522L

D Series Remote Low Side User Manual

October 2014

Page 10

Final Check List

After Connections

1.  Wash out the bin. If desired, the interior of the bin 

could be sanitized.

2.  Locate the ice scoop (if supplied) and have it 

available for use when needed.

Final Check List:

1. 

Is the unit located indoors in a controlled 

environment?

2.  Is the unit located where it can receive adequate 

cooling air?

3. 

Has the correct electrical power been supplied to 

the machine?

4.  Have all the water supply connections been 

made?

5.  Have all the drain connections been made?

6.  Has the unit been leveled?

7.  Have all unpacking materials and tape been 

removed?

8. 

Is the correct switch bezel installed in the trim 

strip?

9.  Is the water pressure adequate?

10. Have the drain connections been checked for 

leaks?

11. Has the bin interior been wiped clean or sanitized?

12. Have any water filter cartridges been replaced?

13. Have all required kits and adapters been properly 

installed?

14. 

Has the ice machine been properly connected to 

the condensing unit or rack?

Control Operation

Use and Operation

Once started, the ice machine will automatically make 

ice until the bin or dispenser is full of ice.

When ice level drops, the ice machine will resume 

making ice.

Caution: Do not place anything on top of the ice 

machine, including the ice scoop. Debris and moisture 

from objects on top of the machine can work their way 

into the cabinet and cause serious damage. Damage 

caused by foreign material is not covered by warranty.

There are four indicator lights at the front of the 

machine that provide information on the condition of 

the machine.

Indicator Lights:

• Power

• Status

• Water

• De-scale & 

Sanitize

Under the door are two switches – On and Off. To 

switch the machine OFF, push and release the Off 

button. The machine will shut off at the end of the next 

cycle.

To switch the machine ON, push and release the 

On button. The machine will go through a start up 

process and then resume ice making.

Switch Door

Summary of Contents for F1222L

Page 1: ...Installation and User s Manual for Remote Low Side Modular Flaked and Nugget Ice Machines Prodigy Plus D Series Models F1222L F1322L N0922L and N1322L ...

Page 2: ...he features needed by customers The features include simple conductivity water level sensing evaporator clearing at shut down photo eye sensing bin control and the ability to add options Contents Installation Page3 Location Page4 Cabinet Layout Page5 Unpacking Page6 Water Page7 Electrical Page8 Refrigeration Page9 Final Check List Page10 Initial Start Up Page11 Scale removal Page12 Check Top Beari...

Page 3: ...commended to remove suspended solids Some filters have treatment in them for suspended solids Check with a water treatment service for a recommendation RO water This machine can be supplied with Reverse Osmosis water but the water conductivity must be no less than 10 microSiemens cm Potential for Airborne Contamination Installing an ice machine near a source of yeast or similar material can result...

Page 4: ... B948S Use KBT38 for a single unit B948S Use KBT38 2X for two units side by side BH1100 BH1300 and BH1600 upright bins include filler panels to accommodate a single 22 inch wide flake or nugget ice machine No adapter is needed Dispenser compatibility Only nugget ice models may be used with ice dispensers Flaked ice is not dispensable ID150 use KBT42 and KDIL PN 150 includes KVS KNUGDIV and R629088...

Page 5: ... 22 70 57 7 FRONT VIEW 24 00 61 LEFT SIDE VIEW 1 59 4 2 63 6 7 14 36 36 5 16 86 42 8 18 81 47 8 21 81 55 4 13 35 33 9 BACK VIEW 5 8 O D REMOTE SUCTION CONNECTION 3 8 O D REMOTE LIQUID LINE CONNECTION 3 4 FPT DRAIN 3 8 FLARE MACHINE WATER INLET 120 VOLT CORD ICE DROP OPENING PLAN VIEW ULTRA SONIC BIN LEVEL SENSOR OPTIONAL 24 00 REF 61 22 00 REF 55 9 2 92 7 4 6 48 16 5 2 81 7 1 4 30 10 9 16 50 41 9 ...

Page 6: ...e adapter Note The machine is heavy Use of a mechanical lift is recommended Position the machine on the bin or adapter Secure with straps from the hardware bag packed with the machine or those supplied with the adapter Remove any plastic covering the stainless steel panels Remove any packaging such as tape or foam blocks that may be near the gear reducer or ice chute Level the bin and ice machine ...

Page 7: ...el and the float valve water inlet orifice Drain There is one FPT condensate drain fitting at the back of the cabinet Tubing Connect the potable water supply to the potable water fitting 3 8 OD copper tubing or the equivalent is recommended Connect the drain tube to the condensate drain fitting Vent this drain tube Do not Tee ice machine drains into the drain tube from the ice storage bin or dispe...

Page 8: ...mmended to avoid unintended shut downs If a dedicated condensing unit is connected to this machine it will have a separate power supply Do not use an extension cord Follow all local and national codes Model Dimensions w x d x h Voltage Volts Hz Phase Min Circuit Ampacity Max Fuse Size cord connected All 22 x 24 x 27 115 60 1 5 8 15 3 8 OD Liquid Line Stub 5 8 OD Suction Line Stub Power Cord ...

Page 9: ...after a rise Roof Attachment Install and attach the remote condensing unit to the roof of the building using the methods and practices of construction that conform to the local building codes including having a roofing contractor secure the condenser to the roof Refrigeration Installation Connections The liquid and suction fittings on the back of the cabinet are stubs The liquid line size is 3 8 O...

Page 10: ...ges been replaced 13 Have all required kits and adapters been properly installed 14 Has the ice machine been properly connected to the condensing unit or rack Control Operation Use and Operation Once started the ice machine will automatically make ice until the bin or dispenser is full of ice When ice level drops the ice machine will resume making ice Caution Do not place anything on top of the ic...

Page 11: ... types of maintenance Remote condensing units need their condenser coils cleaned regularly All models need scale removed from the water system All models require regular sanitization All models require sensor cleaning All models require a top bearing check Maintenance Frequency Scale removal At least twice a year in some water conditions it might be every 3 months The yellow De Scale Sanitize ligh...

Page 12: ...hut off 11 Turn the water supply to the ice machine OFF 12 Drain the water reservoir and evaporator by disconnecting the leg of the hose connected to the water sensor and draining it into the bin or a bucket Return the hose to its original position Discard or melt all ice made during the previous step 13 To sanitize the water system mix a locally approved sanitizing solution An example of a saniti...

Page 13: ...crewing the breaker cover left hand threads 4 Inspect the top of the bearing When new the grease is white over time some gray will appear over the rollers that is normal Add grease to replace gray grease or if gaps between rollers are visible If grease is watery all gray or rust is visible have the bearing replaced See the next page for more information Note When checking the top bearing always in...

Page 14: ...ject grease evenly and thoroughly If the grease is uniformly white no further action is needed If very gray rusty wet or has any embedded metal have the bearing replaced Check Drip Pan For Water Change De Scale Notification Interval This feature is accessible only from standby Status Light Off 1 Press and hold Clean button for 3 seconds Starts the Time to Clean Adjustment State and displays the cu...

Page 15: ...ster turnover for fresher ice Certain dispenser applications where maximum ice level is not desired There are several positions the ice level can be set to including Off knob and label indicators lined up where it fills the bin until the standard bin control shuts the machine off See the kit s instructions for complete details Rotate the adjustment post to the desired ice level The machine will fi...

Page 16: ...ller component indicator light If there is power to the motor check motor windings Code 2 Auger motor draws too many amps controller shuts unit off Check that liquid line valve shuts off tightly Check for damage to gear reducer or auger bearings Bin Eyes Blocked light is On Ice is in the chute No ice in the chute Check position of sensors check sensors for scale build up Everything is in operation...

Page 17: ... The ice machine will make noise when it is in ice making mode The gear reducer will produce sound Some ice making noise could also occur These noises are all normal for this machine Reasons the machine might shut itself off Lack of water Does not make ice Auger motor overloaded Controller self test failure Check the following 1 Has the water supply to the ice machine or building been shut off If ...

Page 18: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 726 8762 www scotsman ice com 17 3532 01 ...

Reviews: