COMPONENT DESCRIPTION
Control Box: Contains the electrical controls
that operate the machine.
High Pressure Cut Out: A manual reset
switch sensing the high side refrigeration
pressure. It is set to shut the machine off at
450 psig.
Evaporator: A vertical stainless steel tube,
refrigerated, and water filled. In it, there is a
stainless steel auger.
Reservoir: Float operated, it maintains the
water level in the evaporator at a constant
level, it also contains the water level sensor.
Water Level Sensor: Senses if there is water
in the reservoir to make ice out of. Will shut
the machine off it there is none.
Ice Discharge Chute: Directs the ice
produced by the evaporator into the storage
bin.
Ice Level Sensor: An electronic "eye", it
senses the presence of ice in the bottom of
the ice discharge chute. Operates to turn the
ice machine on and off automatically as the
level of ice in the bin changes.
Gear Motor: An oil filled, speed reduction
gearbox, driving the auger.
Cleaning Drain Tube: When uncapped and
lowered, drains the evaporator.
Compressor: The refrigerant vapor pump.
Expansion valve: The refrigerant metering
device.
CONTROL BOX
EXPANSION VALVE
WATER LEVEL
SENSOR
RESERVOIR
CLEANING
DRAIN TUBE
EVAPORATOR
GEAR MOTOR
ICE LEVEL
SENSOR
HIGH PRESSURE
CUT OUT
COMPRESSOR
ICE CHUTE
FM1200R
November, 1988
Page 16