COMPONENT DESCRIPTION
Control Box:
Contains the electrical controls that
operate the machine.
High Pressure Cut Out:
An automatic reset
switch sensing the high side refrigeration pressure.
It is set to shut the machine off at 450 psig.
Pump Down Control: An automatic reset pressure
switch connected to the low side of the
refrigeration system. Controls the compressor.
Evaporator:
A vertical stainless steel tube,
refrigerated, and water filled. In it, there is a
stainless steel auger.
Reservoir:
Float operated, it maintains the water
level in the evaporator at a constant level, it also
contains the water level sensor.
Water Level Sensor:
Senses if there is water in
the reservoir to make ice out of. Will shut the
machine off it there is none.
Ice Discharge Chute:
Directs the ice produced by
the evaporator into the storage bin.
Ice Level Sensor:
An electronic “eye”, it senses
the presence of ice in the bottom of the ice
discharge chute. Operates to turn the ice machine
on and off automatically as the level of ice in the
bin changes.
Gear Motor:
An oil filled, speed reduction
gearbox, driving the auger.
Cleaning Drain Tube
: When uncapped and
lowered, drains the evaporator.
Compressor:
The refrigerant vapor pump.
Expansion valve
: The refrigerant metering
device.
CONTROL BOX
EXPANSION VALVE
RESERVOIR
CLEANING
DRAIN TUBE
EVAPORATOR
GEAR MOTOR
ICE LEVEL
SENSOR
HIGH PRESSURE
CUT OUT
COMPRESSOR
ICE CHUTE
NOTE: THERE ARE TWO OF
EACH OF THE LISTED
COMPONENTS IN EACH UNIT
HEAD PRESSURE
CONTROL VALVE
WATER LEVEL
SENSOR