1. The bin control uses devices that sense light,
therefore they must be kept clean enough so that
they can "see". At least twice a year, remove the
bin control sensors from the base of the ice chute,
and wipe the inside clean, as illustrated.
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a
year, the probe should be removed from the
reservoir, and the tip wiped clean of mineral
build-up.
3. The bearing in the breaker should also be
checked at least two times per year.
Check the bearing by:
••
removing the ice chute cover
••
unscrewing the ice sweep
••
removing the water shed
••
unscrewing the breaker cover
••
unscrewing the auger stud
Inspect the assembly, looking for wear.
See Removal and Replacement to replace bearing
or seals. Reverse to reassemble.
4. Clean or replace the air cooled condenser
filter.Clean the air cooled condenser. Use a
vacuum cleaner or coil cleaner if needed.
Do NOT use a wire brush.
5. Check and tighten all bolts and screws.
WATER
RESERVOIR
WATER LEVEL
SENSOR
ICE LEVEL
SENSORS
SLIDE IN
AND OUT
ICE CHUTE
MAINTENANCE
ICE
SWEEP
BREAKER
COVER
BREAKER
NME1250
June 1994
Page 16