WATER RESERVOIR
1. Shut off the water supply to the icemaker.
2. Remove front panel and reservoir cover.
3. Disconnect water inlet compression fitting at
reservoir inlet.
4. To remove float valve, push in on locking tab
and lift float valve out of reservoir tank.
Note: there is a plunger inside the float valve that
is available separately.
5. To remove reservoir, remove drain hose from
reservoir.
6. Remove evaporator inlet hose from reservoir.
7. Remove mounting screws from reservoir
bracket, and remove reservoir from icemaker.
8. Reverse to reassemble.
BIN CONTROLS (Ice Level Sensors)
1. Disconnect electrical power.
2. Remove front panel.
3. Remove control box cover.
4. Locate ice chute, at the base of the chute, in
front of and behind it are two plastic bin control
mounts.
5. Slide each bin control to the left, and in the
control box, disconnect the electrical leads
connecting the bin control to the circuit board.
6. Reverse to reassemble, be certain that the bin
controls are aligned so that the ice level sensors
are visible (centered) through the holes in the cube
chute.
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Control
FLOAT VALVE
PLUNGER
LOCKING
TAB
ICE
CHUTE
SLIDE BIN
CONTROLS IN
AND OUT
NME1250
June 1994