Page 16 of 32
P/N 89332-01 Rev F 7/11
USE OF RESPIRATOR CONTINUED...
DONNING THE FIVE STRAP AV-3000 SURESEAL FACEPIECE
1. Adjust the head straps to the full outward position.
2. Hold the facepiece in one hand while holding the head harness
up and out of the way with other hand. If so equipped, use the
Head Harness Pull Tab on the bottom rear of the head harness
3. Place the facepiece centered on the face with the chin properly
positioned in the chin cup. Verify that no hair or clothing is in-
terfering with the face to facepiece seal. Hold the facepiece in
place with the chin properly located in the chin cup throughout
the donning process.
4. Stroke the head harness over the head and ensure that straps are
lying smooth and flat against the head and neck with no twists.
Verify the head harness is centered and properly located at the
back and base of the head. Maintain the head harness in this
position.
FIGURE 8-A
ADJUST HEAD STRAPS OUT
FIGURE 8-B
HARNESS OUT OF WAY
FIGURE 8-D
HEAD HARNESS POSITION
FIGURE 8-C
CHIN IN CHIN POCKET
NOTE
VERIFY THAT THE TOP CENTER POR-
TION OF THE HEAD HARNESS IS
POSITIONED OVER THE CROWN OF
THE HEAD.
NOTE
ENSURE THAT THE CHIN IS PROPERLY
LOCATED IN THE CHIN POCKET OF
THE FACEPIECE THROUGHOUT THE
DONNING PROCESS.