3 - Starting and Operating
Stationary Air Compressor System Operating Instructions
25
Service Notifications
Service Due
Air Sample 01/18/07
CO Cal 03/18/07
Purifier HRS REM 48
The system will light the SERVICE light on the X4 Con
-
troller panel when one of the service requirements is
due. The operator should report any approaching service
requirements to the System Administrator
in a timely
manner so that the necessary service can be scheduled
and performed.
The X4 Controller tracks the primary Service intervals for
several important service functions including:
• Total Hours of operation time,
• Hours since last compressor service*,
• Hours remaining on Purifier Filters*,
• When the next Air Sample is due*,
• When the next Carbon Monoxide Calibration is
due*.
*The system will light the SERVICE light on the X4
Controller panel when one of these service require
-
ments is due.
The operator must report any Service Due notifications to
the
System Administrator
in a timely manner so that the
necessary service can be scheduled and performed.
Refer to the Service Schedule section of Chapter 4,
OPERATOR MAINTENANCE CHECKS, for details
of the service activities required at prescribed service
intervals.
Operating the Compressor
continued on the next page...
After initial system boot, the operator may press the INFO
button on the X4 Controller to access current Run Time
and Schedule information for the compressor system.
Information Button
4. Press the F1 button under NEXT to see the available
screens. The sequence of displays is as follows:
• Total Hours of Compressor Run Time, HRS / MIN,
• Output Air Temp / CO Level / Dew Point,
• Hour Meter HRS / MIN,
• Hours Remaining on Purifier Filters, HRS / MIN,
• Air Sample Due MM/DD/YY,
• CO Sensor Installation Date, MM/DD/YY,
• DP Sensor Installation Date, MM/DD/YY,
• Time Remaining for Compressor Service , HRS,
• Carbon Monoxide Calibration Due, MM/DD/YY
After the complete sequence, select REPEAT to start the
sequence, or EXIT.
NOTE
If the CO or Dew Point monitor is not installed on
your system, the X4 Controller will display “N/A”
after the parameter on the LCD screen.
Compressor Run Time
HRS / MIN
39 / 14
NEXT
EXIT
NOTE
The INFO function is not available when the
compressor is operating.
1. Turn the external power source ON (wall-mounted
switch).
2. After the X4 Controller completes the system boot,
the display will say, “Press F2 Button Below to
Begin.” Press the F2 key directly below the X4
Controller digital display.
3. The display will show the current Service Due dates
and say, “Push Operate, Info, or Service.” Press INFO
on the keypad. (Remember, you can press BACK at
any time to return to the previous display.)
Summary of Contents for HUSH
Page 2: ......
Page 21: ...3 Starting and Operating Stationary Air Compressor System Operating Instructions 19 NOTES ...
Page 34: ...Stationary Air Compressor System Operating Instructions 4 Operator Maintenance 32 NOTES ...
Page 38: ...Stationary Air Compressor System Operating Instructions 5 Additional Features 36 NOTES ...
Page 45: ...43 Maintenance Record ...
Page 46: ...44 NOTES ...
Page 47: ......