5 - Additional Features
Stationary Air Compressor System Operating Instructions
35
Regulated Low Pressure Outlet and Gauge
The optional low pressure outlet provides compressed,
breathable air at a maximum preset pressure, no higher
than approximately 300 psi (normally set to a maximum
200 psi). The low pressure outlet control panel includes
an air outlet, inlet control valve and a 400 psi gauge.
Always follow the guidelines in this section regarding
auxiliary air outlet use. Refer to “Working with Compressed
Air” in Chapter 3 before operating the low pressure air
supply.
The auxiliary low pressure outlets may be used to
supply respirators or pneumatic tools. Refer to the
user instructions for the supplied air respirators and/or
pneumatic tools before use.
NOTE
The low pressure air supply is breathing air quality
and is NOT lubricated.
1. Ensure that adequate air pressure is available to use
the low pressure outlet. Attach a suitable receiver to
the outlet.
2. To access low pressure air, SLOWLY turn the
Pressure Regulator valve.
3. When finished, hand-tighten any bleed valves and
carefully remove the selected air source from the
low pressure outlet.
If the low pressure air supply outlets are used for
pneumatic tools, DO NOT use the outlets to supply
respirators unless the outlets are cleaned and the
air quality from the outlets is verified as acceptable
according to ANSI/CGA specification G-7.1, Grade
D or better. Lubricants from the pneumatic tools or
tool air lines may contaminate the low pressure air
supply outlets for breathing air usage which can result
in serious injury or death to respirator users.
NEVER use hoses to supply respirator air if they
have been used to supply air to pneumatic tools.
The pneumatic tool hoses may be contaminated
with lubricant making them unsuitable for supplying
breathing air.
If the auxiliary low pressure outlet is used to supply
air for pneumatic tools, the air supply must still be
maintained to breathing air standard. Lubrication for
the pneumatic tools must be added after the auxiliary
low pressure outlets. Failure to follow this precaution
may contaminate air supply, which can result in
personal injury or death.
Regulated (Low Pressure) Controls
1)
Inlet Control Valve
2)
Variable Pressure Regulator
3)
Low Pressure Gauge
Low Pressure Outlet is located
on the back of the control panel (not shown)
Summary of Contents for HUSH
Page 2: ......
Page 21: ...3 Starting and Operating Stationary Air Compressor System Operating Instructions 19 NOTES ...
Page 34: ...Stationary Air Compressor System Operating Instructions 4 Operator Maintenance 32 NOTES ...
Page 38: ...Stationary Air Compressor System Operating Instructions 5 Additional Features 36 NOTES ...
Page 45: ...43 Maintenance Record ...
Page 46: ...44 NOTES ...
Page 47: ......