CHAPTER 2: INSTALLATION
087-0067 REV A
SCOTT SAFETY
Locating and Securing
the Devices
This section covers locating and securing the devices.
Depending on the specific customer order the devices may vary.
Locating the Charge
Station
This section covers the selection of a proper location for the Charge Station.
Warning: Make sure there is nothing close to or on top of the Charge Station that
could interfere with normal operations. For proper operation, the minimum clearance
of 24” must be established at installation on all sides and above the Charge Station
and must be maintained.
Securing the Charge
Station
This section covers securing the Charge Station. Each Charge Station ships with 4
bolts used to secure the device. The bolts are inserted through the devices feet into
concrete. The bolts are 58113 HH Wedge Anchor GR5 Z (5/8-11 X 3 Hex Head
Wedge Anchor Bolt Grade 5 Zinc).
Warning: The Charge Station must be anchored to the floor using the supplied bolts.
Failure to do so could result in injury or death.
Locating the
Compressor
This section covers the selection of a proper location for the Compressor.
Ensure the following items are adhered to when selecting a proper location:
•
A relatively clean, debris free and dry shelter
•
Sufficient ambient air for compressor cooling
•
A sufficient source of clean, compressor intake air
•
An appropriate power supply
•
An appropriate means to handle the water/oil mixture discharged from the auto
drain reservoir
A debris free environment is important because the Compressor draws cooling air
near floor level. Paper, dust, and other light-weight items allowed under the device
might be entrained in the cooling air stream and be drawn into the device. Large
objects might cause compressor fan damage or impede heat transfer efficiency which
could lead to a multitude of mechanical problems.
Since the Compressor is an air-cooled device, the heat of compression is rejected to
the surrounding air. It is important to locate the device in a very large room or provide
enough ventilation to maintain cooling air temperature below 100
°
F.
It is desirable to locate the Compressor in an environment free of high CO, CO
2
, and
other air contaminants. When the environment is less than desirable, provisions
should be made to permit the connection of an external source of air.
Warning: Make sure there is nothing close to or on top of the Compressor that could
interfere with the air flow. For proper operation, the minimum clearance of 24” must
Summary of Contents for HushAir Connect 7500
Page 1: ...User Guide 087 0067 Rev A HushAir Connect 7500 COMPRESSOR SYSTEM ...
Page 2: ......
Page 3: ...HushAir Connect 7500 User Guide COMPRESSOR SYSTEM 087 0067 Rev A ...
Page 8: ...IV CONTENTS 087 0067 REV A SCOTT SAFETY ...
Page 12: ...X LIST OF TABLES 087 0067 REV A SCOTT SAFETY ...
Page 42: ...20 CHAPTER 2 INSTALLATION 087 0067 REV A SCOTT SAFETY ...
Page 73: ...Configuring the System 51 SCOTT SAFETY 087 0067 REV A Figure 27 Override Status Screen ...
Page 106: ...84 CHAPTER 5 MAINTENANCE 087 0067 REV A SCOTT SAFETY Figure 48 Oil Drain Location 3 1 2 ...
Page 112: ...90 APPENDIX A SPECIFICATIONS 087 0067 REV A SCOTT SAFETY ...
Page 119: ......