Page 9 of 44

P/N 595189-01  Rev A  4/10

7

  Hansen is a registered trademark of Tuthill Corporation.

8

  Foster is a registered trademark of Foster Manufacturing Co., Inc. 

9

  Schrader is a registered trademark of Scovill, Inc. 

10 

Cejn is a registered trademark of Cejn AB

Single Plug Version         Dual Plug Version

AIRLINE CONNECTION HOSES

figure 1

WArning

do  noT  uSe  oTher  hoSeS,  couPlingS 

or AdAPTerS To ATTAch incomPATible 

comPonenTS  To  The  reSPirATor.  in-

comPATible  comPonenTS  mAy  reduce 

The AbiliTy of The reSPirATor To SuP-

Ply  Air  And  mAy  exPoSe  The  uSer  To 

The  hAZArdouS  ATmoSPhere  Which 

could  reSulT  in  SeriouS  inJury  or 

deATh.

WArning 

The uSer of ThiS reSPirATor mAy hAve 

To  diSconnecT  The  hoSe  couPling 

Suddenly And  under  STreSSful  con-

diTionS. The uSer muST be Able To diS-

connecT The couPling under The con-

diTionS  Which  mAy  be  encounTered 

during uSe, for exAmPle, WiThouT be-

ing  Able  To  See  The  couPling,  WiTh 

gloveS  on,  WiTh  one  hAnd,  eTc.  fAil-

ure To AdeQuATely TrAin The uSer mAy 

reSulT in SeriouS inJury or deATh.

The 30010-Series, 26370-Series, 200820-Series, and 803904-01 air 

supply  hoses  may  be  interchanged  to  supply  a  single  SKA-PAK AT 

respirator, and, except for these, different types of supply hose may 

NOT be mixed.

The  30010  series  hose  utilize  a  Hansen

7

  brass  disconnect  coupling. 

The  26370  series  hose  utilizes  a  stainless  steel  Foster

8

  disconnect 

coupling. The 26369 series hose utilizes a stainless steel Hansen HK 

disconnect coupling. The 30020 series hose utilizes a steel Schrader

9

 

disconnect coupling. The 805659 series hose utilizes a brass Cejn

10

 

disconnect  coupling.  One  of  these  types  of  couplings  is  located  on 

the end of the airline connection hose and at the ends of each seg-

ment  of  air  supply  hose.  Dual  airline  connection  hoses  terminate  in 

two couplings, both of which are of one of the above types. 

The air supply hose segments must be directly coupled to the airline 

connection hose at the waist belt of the respirator, to each other and 

to the air supply system. Adapters shall not be used. 

After  determining  which  type  of  air  supply  hose  and  couplings  are 

used with your respirator, locate the appropriate section of Table 1 on 

page 23 of this instruction sheet for detailed instructions on operating 

the coupling and for limitations on air supply hose length and number 

of segments allowed. 

figure 2

Summary of Contents for SKA-PAK AT

Page 1: ...H ELECTRONIC ALARM WARNING IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN PERSONAL INJURY OR DEATH IMPROPER USE INCLUDES BUT IS NOT LIMITED TO USE WITHOUT ADEQUATE TRAINING DISREGARD OF THE WARNINGS AN...

Page 2: ...This respirator is not to be used under water for interior structural fire fighting or for any other purpose not authorized by the organized respiratory protection program that applies specifi cally t...

Page 3: ...ration have one of five types of quick connect plugs and come in single or dual plug versions Dual plug versions provide a facil ity for transition between redundant air supply hoses On both the singl...

Page 4: ...h a multipurpose Full Body Harness P N 805061 04 This harness is intended to be used only in accordance with both the user s respira tory protection program and fall protection program For additional...

Page 5: ...this or similar equipment 5 Whether or not the cylinder is fully charged at the start of the use period 6 The possible presence in the compressed air of carbon dioxide concentrations greater than 04 n...

Page 6: ...er After passing the NEGATIVE PRESSURE LEAK TEST the facepiece size selected must be verified by successfully passing a respirator Quantitative Fit Test When fit testing for Open Circuit Pressure Dema...

Page 7: ...TEST and the Quantitative Fit Test If leakage is still detected either per these user instructions or the OSHA fit testing process the use of Mask Seal Kit P N 805655 01 may be required to attain a p...

Page 8: ...eratures at or below freezing 32 F 0 C the condensation may freeze inside the air supply lines or inside the respirator possibly causing the flow of breathing air to be reduced or to stop completely N...

Page 9: ...03904 01 air supply hoses may be interchanged to supply a single SKA PAK AT respirator and except for these different types of supply hose may NOT be mixed The 30010 series hose utilize a Hansen7 bras...

Page 10: ...with the body of socket A as described in step 1 Slide sleeve B away from the body toward the supply hose to release the plug fitting from the socket IF IT IS NOT PRACTICAL TO SEE THE ALIGNMENT NOTCH...

Page 11: ...e reducer using moderate force NOTES 11 SCOTT Part Number stamped into end of hose See FIGURE 2 12 SCOTT Part Number stamped into hose within 6 inches of either end 13 Specify silicone seals if orderi...

Page 12: ...one of the following 9 volt batteries Energizer Alkaline No 522 or EN22 Duracell Alkaline No PC1604 or MN1604 or for increased service life use Ultralife Lithium Bat tery No U9VL Be sure battery is p...

Page 13: ...Any trapped air will flow from the regulator Close the purge valve by rotating the knob to the full clockwise position when air flow stops CYLINDER INSPECTION NOTE IT IS THE RESPONSIBILITY OF THE USER...

Page 14: ...on Page 4 and referenced in the DBI SALA full body harness user instructions SCOTT P N 89497 01 pro vided with the harness If any damage is found do not use the harness NOTE IF THE FULL BODY HARNESS H...

Page 15: ...er and valve assembly is properly fitted to the harness Inspect the cylinder clamps Both clamps must be tight and hold the cylinder to the harness securely Tighten as necessary See FIGURE 6B FIGURE 6B...

Page 16: ...ted on the nipple coupling that connects the pressure reducer to the cylinder valve To expose the threads and the gasket for inspection grasp the hand wheel coupling on the pressure reducer and turn t...

Page 17: ...re must be taken to remove any dirt accumulations or obstructions from the fittings without allowing them to enter the air supply hose 6 Inspect the hose assembly that connects the pressure reducer to...

Page 18: ...the facepiece as follows 1 Inspect the facepiece seal and other rubber components for de formation wear damage or cracks 2 Inspect the lens for cracks gouges scratches or any condition that could impa...

Page 19: ...Cup is standard on the SCOTT AV 2000 Weld O Vista and AV 3000 full facepieces and optional on the SCOTT O VISTA full facepiece a SCOTT AV 3000 and AV 3000 SureSeal Facepieces are avail able with two d...

Page 20: ...ize No air flow shall be detected at this time Inhale sharply to start the flow of air then take one breath and hold NOTE If the purge valve is adjusted to produce a flow it may not be possible to res...

Page 21: ...OVIDE ADEQUATE PROTECTION FROM THE HAZARDOUS ATMOSPHERE WHICH MAY RESULT IN SERIOUS INJURY OR DEATH WARNING USE ONLY BREATHING AIR WHICH MEETS THE REQUIREMENTS AS DESCRIBED IN THE AIR SUPPLY REQUIREME...

Page 22: ...such that the facepiece is toward the front of the wearer and the air supply cylinder is next to the left foot Pass the shoulder strap over the left shoulder and head onto the right shoulder Draw the...

Page 23: ...ction or interference is suspected do not use the respirator until the problem is corrected Position the required length of air supply hose and prepare it for use by connecting the segments to each ot...

Page 24: ...o the operating pressure of the respirator Repeat this step for each air supply hose and each air supply system to be used FIGURE 17 CONNECTING SUPPLY HOSE AND STANDBY CONDITION SHOWN WITH OPTIONAL NE...

Page 25: ...ssure reducer is tight and that the breathing regulator purge valve red knob on regulator is closed knob turned fully clockwise Depress the air saver donning switch and release Connect the sup ply hos...

Page 26: ...head harness to the head Periodically repeating the fit testing is required to identify any physical changes of the user such as those listed above which could affect the fit of the facepiece NOTE IF...

Page 27: ...h chin properly located in the chin pocket while pulling the head harness over the top of the head Verify that no hair or clothing is interfering with the face to facepiece seal See FIGURE 19A 4 Tight...

Page 28: ...n place with the chin properly located in the chin cup throughout the donning process 4 Stroke the head harness over the head and ensure that straps are lying smooth and flat against the head and neck...

Page 29: ...temple strap end toward the rear of the head Alternate hands to maintain the facepiece position on the face 7 Verify the proper location of the face in the facepiece and the chin in the chin cup Tigh...

Page 30: ...your head If necessary adjust the head harness net to the center of the crown of the head 10 Verify the proper location of the face in the facepiece and the chin in the chin cup Retighten the straps i...

Page 31: ...o low on the face as evidenced by pres sure on the forehead or the facepiece making contact with the throat area permitting a break in the seal The illustrations below depict the AV 3000 SureSeal but...

Page 32: ...ted as described under PREPARATION FOR USE 3 FULLY OPEN THE CYLINDER VALVE by turning the valve knob to the full counterclockwise position This will require approxi mately 2 1 2 complete rotations of...

Page 33: ...on hose and transfer to another air supply hose is an ticipated during use of the respirator the user shall check the operation of the respirator as described above with each air supply hose and each...

Page 34: ...knob The ELECTRONIC alarm shall flash both lights for approximately five seconds to ini tialize and stop The cylinder pressure gauge on the ELECTRONIC alarm shall read FULL The VIBRALERT shall NOT act...

Page 35: ...xit from the area requiring respiratory protection is normally made by retracing the path used during entry so that exit can be made while air is supplied by the air supply system through the air supp...

Page 36: ...upply hose for egress for instance if the hose is entangled or if it is necessary to exit by a different route the user shall disconnect the hose and immediately leave the area requiring respiratory p...

Page 37: ...C Where it is expected that the respirator will be used in ambient temperatures near or below freezing the respirator shall be equipped with a Nose cup Assembly to reduce the formation of vision impa...

Page 38: ...FAILURE TO THOROUGHLY RINSE AND COMPLETELY DRY THE ENTIRE FACEPIECE ASSEMBLY MAY ALLOW A BUILDUP OF DE TERGENTS AND OR DISINFECTING AGENTS WHICH COULD DAMAGE FACEPIECE COM PONENTS CLEANING THE FACEPI...

Page 39: ...ening See FIGURE 22 Be sure to cover internal components completely 5 Follow the user instructions for the SCOTT recommended cleaner A specific contact time may be required for sanitizing or disinfect...

Page 40: ...ORAGE WITH OUT THOROUGHLY DRYING THEM MAY RE SULT IN CORROSION OR OTHER DAMAGE WHICH COULD CAUSE A MALFUNCTION OF THE RESPIRATOR SUCH A MALFUNC TION MAY RESULT IN SERIOUS INJURY OR DEATH WARNING PLACI...

Page 41: ...ed Test Equipment at least every two years16 However heavy use may require more frequent testing This recommendation is in addition to all other cleaning and maintenance procedures A manual covering t...

Page 42: ...atter paint spray and abrasion 5 Dual airline connection hose assembly for redundant air sup ply hoses or to facilitate transfer between hoses H Type P N 804319 01 with standard Hansen fittings S Type...

Page 43: ...D AIR SUPPLY APPROVED FOR USE AT TEMPERATURES ABOVE 25 F 32 C APPROVED ONLY WHEN THE COMPRESSED AIR CYLINDER IS FULLY CHARGED WITH AIR MEETING THE RE QUIREMENTS OF THE COMPRESSED GAS ASSOCIATION SPECI...

Page 44: ...Page 44 of 44 P N 595189 01 Rev A 4 10 Health Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 Telephone 1 800 247 7257 FAX 704 291 8330 www scotthealthsafety com Printed in USA...

Reviews: