SCOTTY ProMin HD Equipment Manual
24
All rights reserved.
7.7
Power Requirements – AC variant
Voltage Range:
100V … 240V AC
Max. Current:
1.4A
Frequency Range:
47Hz … 63Hz
Power consumption: 50W (typical operation, no external load)
70W (internal maximum, no external load)
100W (typical, with maximum external load)
When power is applied, the system will wait for activation via the front power
button or the power button input.
As order specified option “Auto Start” is available: The system will start
immediately when power is applied.
Temperature monitoring turns off the unit if the system temperature violates
the operation limits.