background image

10

IN

 AU

STRAL

IA

PR

OU

DLY BUILT

19. AMX Device Discovery

• 

This feature allows the IP CONNECT module to be identified by AMX AV Control Systems.
When polled the IP CONNECT module responds with a Beacon message which contains 
device specific information. (Eg Make, Model, Version) With this information the AMX 
system is able to then configure itself with the correct protocol to be able to control the IP 
Connect Module.

• 

The protocol works for any of the Serial ports, and over TCP/IP.

• 

The AMX “Device Discovery White Paper.Doc” defines, The Dynamic Device Discovery 
Protocol - the connection methods and data interactions required to dynamically connect 
a third party device to a NetLinx Master via either serial or IP connectivity.

• 

AMX Discovery is enabled using Register 80 or via internal web browser

Continued Over.../

20. FACTORY RESET SWITCH

• 

Single long press for 5 seconds approximately

 - Factory Default Mode selected.
 - LED double flashes.
 - Pressing button again exits mode.
 - Power cycle off / on for 10 seconds or 

receiving an IR command exits this mode.

• 

Puts module into Static IP Mode

 - Default IP address is 192.168.1.253
 - Module can be accessed via web browser

• 

Single short press for 3 seconds approximately

 - Screen Rattle command.
 - 3 seconds down 1 second up.
 - LED single flashes while in this function.
 - Pressing button again stops screen.
 - Function is exited when screen operation finished or another screen operate 

command is acted on.

 

 

 

 

 

e.

 

Triple short press for 2 seconds approximately per button press 

Lifter Down command. Screen travels to down limit.  

LED single flashes while in this function.  

Pressing button again stops screen.  

Function also exited when screen operation finished or another 

screen operate command is acted on 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting Up Lifter 
21. Initial Set up

• 

After installing projector lift you will need to reset encoder

• 

Apply power to Motor Controller

• 

Send the lifter down via the IR remote control for 5 seconds, by pressing Down button on IR 
remote control

• 

Stop lifter by pressing stop button on IR remote

• 

Send the lifter to top position by pressing Up button on IR remote control

22. SETTING THE SERVICE POSITION (BOTTOM)

• 

Send the lifter to service position

• 

Using the IR remote control using Group One buttons push buttons rapidly in this sequence

• 

Stop – Stop – Stop – Down

• 

Lifter will now move to bottom limit

• 

If this position requires adjustment, this is done via the physical limits on the motor

• 

White Limit adjusts Bottom Limit

• 

Using the supplied limit adjusting tool

• 

Clockwise rotation increases rotation of motor, moves the lifter further down

• 

Anti clockwise rotation reduces rotation of motor

• 

Can I adjust the switch while the lifter is sitting on the limit - ie fully up or down?

• 

Clockwise adjustment? – YES. But it is better to back the lifter away from the limit and then 
adjust

• 

Double short press for 2 seconds approximately per button press

 - Screen Up command. Screen travels to up limit.
 - LED single flashes while in this function. Pressing button again stops screen.
 - Function is exited when screen travels to up position or another screen operate 

command is sent.

• 

Triple short press for 2 seconds approximately per button press

 - Screen Down command. Screen travels to down limit.
 - LED single flashes while in this function.
 - Pressing button again stops screen.
 - Function also exited when screen operation finished or another screen operate 

command is acted on.

 

INSTRUCTIONS - 

INTERFIT 

PROJECTOR LIFT – FVI and HTI Series

Summary of Contents for INTERFIT FVI Series

Page 1: ...he unit within the eiling space Following are some accepted install practices lease Note You MUST utilise the four 4 Black Steel L Brackets and the 12mm bolts o secure this lifter into the ceiling The...

Page 2: ...stallation height and then insert the rods ow attached to the lifter unit acket till the ceiling edge trims are firmly eiling material then wind the upper nuts down to the roof space but this is not a...

Page 3: ...Right Hand Side One switch is accessible either when the lift is down or when the side cover is removed WHICH SWITCH IS FOR UP AND DOWN Down switch Bottom Limit WHITE The one closest to the rear of th...

Page 4: ...approximately based 24 AWG gauge cable 6500105 Connect IP 4 Core Motor Controller All inputs on module 1 are accessed by removing right hand end cap of screen canister Continued Over 1 CONTACT CLOSE I...

Page 5: ...c Connect software Software looks for Connect IP products on the network Maximum 2 Screen shot below showing that software has found IP connect motor controller showing allocated IP Address Connect to...

Page 6: ...Partial 1 2 operate as stop unless programmed 8 Connect Internal Web Browser a Select Direct Control from Control Menu b Direct Control Screen shown below c Partial 1 2 act as stop command unless part...

Page 7: ...ings on drop down menu c Select Module ID or MAF address and load d This menu will enable changes of features within the module e 127 registers in total f Screen shot below showing register page 13 Re...

Page 8: ...A comma delimiter is included An Example is shown below 1 3 45 CR LF FORMAT The stream is made up of messages A message consists of 1 to 80 printable ascii characters followed by and end of message An...

Page 9: ...uffer contains the Module ID 1 byte and Module Status 2 bytes COMMAND 050 COMMAND VALUE 1 VALUE 2 VALUE 3 150 Status Module ID Module Status Register 0x20 Response from module e g 150 1 1 6 value 6 in...

Page 10: ...n stops screen Function also exited when screen operation finished or another screen operate command is acted on Setting Up Lifter 21 Initial Set up After installing projector lift you will need to re...

Page 11: ...INTENANCE Screen Technics lifters are designed to provide many years of trouble free operation If the unit ever does anything abnormal or has been affected by an outside event the unit should be isola...

Reviews: