background image

ScreenLine

4

PLEATED BLIND

technical specification

SL20M   SL22M plissé

Performance characteristic of the Verosol

®

fabric 

Pleated Verosol

®

Solar

Light Solar

Solar

Light 

Fabric

reflection %

reflection %

absorbing %

transmission %

transmission %

812

71

66

20

9

9

816

52

50

28

20

22

878

74

74

21

5

5

Performance characteristic of the Vanity fabric

Pleated Vanity 

Light reflection %

Light absorbing %

Light transmission %

Fabric 

White C000

46

4

51

Cream C010

40

13

46

Bottom rail

Extruded aluminium A6063S-T5 alloy.

Dimensions: width 14 mm, height 30 mm.

Manufactured in two interlocking profiles.

Powder coated to colour aluminium grey, white or beige.

Internal cord

Thermo-fixed 100% polyester internal cord, with excellent dimensional stability. 1.0 mm diame-

ter – colour white. High resistance performance and very little shrinkage effects at high tempe-

rature.

Spacer bar

Extruded aluminium.

SL20C System Dimensions: 20 x 6,5 mm; Upper: extruded open spacer bar; Lower: extruded “U”

shaped spacer bar with 2 mm clipping projection; Sides: “L” shaped side spacer with 8 mm pro-

jection on one side.

SL22C System Dimensions: 22 x 6,5 mm; Upper: extruded open spacer bar; Lower: extruded “U”

shaped spacer bar with 2 mm clipping projection; Sides: “C” shaped side spacer with 8 mm pro-

jection on each side. 

Control accessories

Control unit 

For use in the application of centralization of several blinds or bus control.

It is possible to connect a maximum of 4 blinds. Possible connections: power supply, single switch

and remote signal from other control units, and output to motor. Due to its small dimensions

(40x40x20 mm) it can be easily contained in the wall electric box. Equipped with internal safety

fuse 6,3 A.

Power supply

230V AC Mains voltage input / 24V DC +/- 5% output, 2A. Protection fuse 3,15 A delayed, for

maximum 4 blinds. Dimensions: 110 (130 mm with fixing projections) x85x50 mm (height)

SL

20M 

plissé

SL

22M 

plissé

SL20 22M plissé_GB  15-05-2007  9:45  Pagina 4

Summary of Contents for SL20M

Page 1: ...635 info pellini net SL20M SL22M pliss MTL015GB Edition 05 07 www pellini net visual design stefanosiboni it Technical Catalogue english double glazed unit 20 mm 22 mm ScreenLine SL22M pliss SL20M pli...

Page 2: ...in order to avoid excessive stress on the cords and to guarantee a longer life to the compo nents Faster speed for raising and lowering The motor and the entire electronic blind management system are...

Page 3: ...rollers double bearings in output Total Ratio 214 1 95 1 in the reducer 2 25 1 in the corner key Encoder Magnetic encoder in Neodymium with a very high magnetic field with a resistance strength up to...

Page 4: ...d aluminium SL20C System Dimensions 20 x 6 5 mm Upper extruded open spacer bar Lower extruded U shaped spacer bar with 2 mm clipping projection Sides L shaped side spacer with 8 mm pro jection on one...

Page 5: ...ScreenLine 5 SL20 22M pliss _GB 15 05 2007 9 45 Pagina 5...

Page 6: ...Internal motor with encoder SL1708 Plastic corner key 20x6 5 mm SL1740 Extruded L shaped spacer bar 20x6 5 mm SL1217 ScreenLine plastic label 14 mm Verosol pleated fabric SL1165 1 mm internal cord SL1...

Page 7: ...ted SL1052 Calibrated tube SL1854 Internal motor with encoder SL1820 Plastic corner key 22 mm SL1772 Extruded C shaped spacer bar 22x6 5 mm SL1217 ScreenLine plastic label 14 mm Verosol pleated fabric...

Page 8: ...EXTRUDED L SHAPED SPACER BAR EXTRUDED U SPACER BAR 2 6 5 12 OUT IN 14 mm PLEAT 20 12 55 SL22M pliss double glazed unit 8 3 12 6 5 EXTRUDED C SPACER BAR EXTRUDED U SPACER BAR 2 6 5 12 OUT IN 14 mm PLEA...

Page 9: ...ss dimensions for double glazing 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 30 35 40 45 50 60 70 80 90 100 110 120 130 140 150 Width cm Height cm W H SL22M pl...

Page 10: ...d to insert the corner key into the bottom of each side spacer bar fill them with the molecular sieve and block the open end with butyl or fibres to avoid any loss of sieve during further operations A...

Page 11: ...e pressing system Gas filling Using the appropriate equipment and in accordance with the standard procedure replace the internal air with argon Testing After the press operation but prior to applying...

Page 12: ...on tubes should remain straight and not damaged Where the final seal is applied horizontally any glass deflection should be corrected by equalisation after curing i e the glass surfaces should be para...

Page 13: ...in order to avoid any friction between bottom rail and glass surface during raising and lowering Transport and storage For transport and storage procedures please check the recom mendations contained...

Page 14: ...marked as MOTOR Fuse 6 3 A Working temperature 20 60 C 14 Note The REMOTE terminal is available to allow the installer the opportunity to meet the client s requirements for a variety of group control...

Page 15: ...cks one for the main s power supply connection and the other for the 24V dc output It can supply up to a maximum of 4 motors Technical features Dimensions mm 110 130 included fixing fins x85x50 height...

Page 16: ...malfunction Cover the area around the connection with more secondary sealant to ensure no possibility of water penetration creating a short circuit after glazing Ensure that there is no possibility of...

Page 17: ...oid sudden stops which results in less stress on the components When the motor experiences a sudden increase in the energy absorption or a remarkable reduction of the motor speed as a possible result...

Page 18: ...ScreenLine 19 SL20M SL22M pliss single control 230V ac SL20 22M pliss _GB 15 05 2007 9 45 Pagina 19...

Page 19: ...SL20M SL22M pliss centralised control with switch and or remote control 20 ScreenLine 230V ac SL20 22M pliss _GB 15 05 2007 9 45 Pagina 20...

Page 20: ...c A B G ScreenLine 21 SL20M SL22M pliss centralised radio control with without switches for two groups A B G No 1 group control No 2 group control General group control SL20 22M pliss _GB 15 05 2007 9...

Page 21: ...and single control for two groups 22 ScreenLine 230V ac 230V ac B A G C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 A B No 1 group control No 2 group control C x G Single blind control General group control SL20 22...

Page 22: ...M pliss centralised control with switch and or remote control and single switch 230V ac 230V ac G C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C x G Single blind control General group control SL20 22M pliss _GB 15...

Page 23: ...6 5mm spacer bars 12mm sight line ONLY Fill in the secondary sealant depth column where you require a different secondary sealant depth the size of the blind provided will be adjusted to meet our own...

Page 24: ...the Purchaser who within 3 three days after receipt must inform the Company about any defect damage theft shortage and delays occurred during the transport in order for the latter to file a complaint...

Page 25: ...might cause delays to the Company to settle the complaint It is agreed that should this be the case the Company will not be liable for such delays Complaints regarding Products having been cut used a...

Reviews: