background image

ScreenLine

23

SL27M plissé    

centralised contr

ol with switch and / or r

emote contr

ol and single switch 

230V ac

230V ac

G

C

1

C

2

C

3

C

4

C

5

C

6

C

7

C

8

C

x

G

Single blind contr

ol 

General  gr

oup contr

ol

SL27M plissé_GB  15-05-2007  9:29  Pagina 23

Summary of Contents for SL27M

Page 1: ...F 39 0377 437635 info pellini net SL27M pliss MTL012GB Edition 05 07 www pellini net visual design stefanosiboni it Technical Catalogue english ScreenLine SL27M pliss PLEATED BLIND double glazed unit...

Page 2: ...bottom limits in order to avoid excessive stress on the cords and to guarantee a longer life to the compo nents The faster speed allows quicker raising and lowering The motor and the entire electronic...

Page 3: ...gs in output Ratio 270 1 Encoder Magnetic encoder in Neodymium with a very high magnetic field with a resistance strength up to 120 C Fixed firmly on the motor shaft via a brass ring Electronic card M...

Page 4: ...e performance and very little shrinkage effects at high tempe rature Spacer bar Extruded aluminium Dimension 27 x 8 mm Upper extruded open spacer bar 27 x 8 mm Lower extruded U shaped spacer bar with...

Page 5: ...ScreenLine 5 SL27M pliss _GB 15 05 2007 9 29 Pagina 5...

Page 6: ...2 Adhesive plastic tape 19 5 mm SL1536 Head rail painted SL1061 5 mm hexagonal shaft SL1774 Internal motor with encoder SL1752 Bottom rail end cap SL1217 ScreenLine plastic label SL1197 Bottom rail co...

Page 7: ...Glass H 3 8 12 12 3 12 EXTRUDED U SPACER BAR 30 8 4 OUT IN 20 mm PLEAT 12 39 27 EXTRUDED OPEN SPACER BAR EXTRUDED C SPACER BAR Glass W Glass H 3 8 12 12 3 12 30 8 4 OUT IN 20 mm PLEAT 71 12 27 EXTRUD...

Page 8: ...rail feasibility 3 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 32 37 42 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 Width cm Height cm W...

Page 9: ...ommended to insert the corner key into the bottom of each side spacer bar fill them with the molecular sieve and block the open end with butyl or fibres to avoid any loss of sieve during further opera...

Page 10: ...ine pressing system Gas filling Using the appropriate equipment and in accordance with the standard procedure replace the internal air with argon Testing After the press operation but prior to applyin...

Page 11: ...con tubes should remain straight and not damaged Where the final seal is applied horizontally any glass deflection should be corrected by equalisation after curing i e the glass surfaces should be par...

Page 12: ...e in order to avoid any friction between bottom rail and glass surface during raising and lowering Transport and Storage For transport and storage procedures please check the recom mendations containe...

Page 13: ...arked as MOTOR Fuse 6 3 A Working temperature 20 60 C 14 Note The REMOTE terminal is available to allow the installer the opportunity to meet the client s requirements for a variety of group control c...

Page 14: ...ks one for the mains power supply connection and the other for the 24V dc output It can supply up to a maximum of 4 motors Technical features Dimensions mm 110 130 included fixing fins x85x50 height T...

Page 15: ...connection with more secondary sealant to ensure no possibility of water penetration creating a short circuit after glazing Ensure that there is no possibility of the wires being damage by the framing...

Page 16: ...and so avoid sudden stops which results in less stress on the components When the motor experiences a sudden increase in the energy absorption or a remarkable reduction of the motor speed as a possibl...

Page 17: ...ScreenLine 19 SL27M pliss single control 230V ac SL27M pliss _GB 15 05 2007 9 29 Pagina 19...

Page 18: ...SL27M pliss centralised control with switch and or remote control 20 ScreenLine 230V ac SL27M pliss _GB 15 05 2007 9 29 Pagina 20...

Page 19: ...e 21 SL27M pliss centralised radio control with without switches for two groups 230V ac 230V ac A B G A B G No 1 group control No 2 group control General group control SL27M pliss _GB 15 05 2007 9 29...

Page 20: ...nd single control for two groups 22 ScreenLine 230V ac 230V ac B C 1 A G C 2 C 3 C 4 C 5 C 6 C 7 C 8 A B No 1 group control No 2 group control C x G Single blind control General group control SL27M pl...

Page 21: ...pliss centralised control with switch and or remote control and single switch 230V ac 230V ac G C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C x G Single blind control General group control SL27M pliss _GB 15 05...

Page 22: ...o the Purchaser who within 3 three days after receipt must inform the Company about any defect damage theft shortage and delays occurred during the transport in order for the latter to file a complain...

Page 23: ...t cause delays to the Company to settle the complaint It is agreed that should this be the case the Company will not be liable for such delays Complaints regarding Products having been cut used and or...

Reviews: