Above Ground Installation

(Timber Support)

The above ground installation on an existing concrete slab can be performed by either using a combination of the 
arrangement in Diagram A or using a timber support structure in lieu of the sand/cement fill as shown in Diagram B. 
Build a support timber structure using heights for the seat and reclining area taken from the Spa pool. Allow 50mm 
under the base for the cement support.

Carefully reconstruct the seat area, because the seat area plus the base will be taking the major share of the 
weight. The reclining area will be supported where it touches the horizontal support structure.When you are satisfied 
the Spa pool will sit level and be firmly supported, remove the Spa pool from the frame and mix the cement for the 
base. Heap the wet cement mixture in place and position the Spa pool in the support structure. Move the Spa pool 
about until it is evenly supported and level.

Complete the plumbing and structural surround after the base has set. Insulate around the Spa pool shell  
where practicable.

Pg. 12

Installing Plumbed Shells

sand and cement -7:1 mix

treated timber

(brick recommended)

retain spa pool rim with timber trim

tapered packer

Diagram B

treated timber

(brick recommended)

Summary of Contents for Portable and In-Ground Spas

Page 1: ...Portable and In Ground Spas Operating Manual The Best Built Spas in the World TM...

Page 2: ...proper care and service of your new Spa and the correct chemical maintenance of the water your Spa will provide years of enjoyment Please take time to read this manual carefully before operating your...

Page 3: ...talling Plumbed Shells 11 13 Plumbing of In Ground Spas 14 Electrical Connections 15 16 Requirements Note To Electrician Electrical Terminations Touchpad Control Centre 16 Checklist Prior To Filling Y...

Page 4: ...Light 26 27 Changing The Coloured Lens Replacing The Light Globe Inside Deluxe Models Only Outside Standard Models Only Jet Information Ozonator 28 Air Control 29 Aromatherapy Dispenser 29 Air Injecto...

Page 5: ...s lights and diagnostic codes ControlBox wherepowersupply blower ozone if used and circulation pump are connected Located in the engine bay of your spa Main and Boost Pump if applicable Located in the...

Page 6: ...or additional chemical requirements when using ozone contact your Dealer There are two types of ozone units used in SCS spas For further details see the Ozonator section on page 28 of this manual Type...

Page 7: ...de of the Spa This canister holds the Aroma Beads To access the canister unscrew the cap in an anti clockwise direction Ensure blower is not operational when removing cap JetPak TM if fitted the ultim...

Page 8: ...viced at the recommended intervals as detailed in the Spa s manual or Warranty will ensure your Warranty remains valid Access IMPORTANT NOTE As stated in the Pre Delivery Manual when installing the Sp...

Page 9: ...ylic on the base of the Skimmer box where the filters fit into the plumbing Identification Compliance Label Portable Spas SCS Industries Portable Spas come complete with their own Identification Compl...

Page 10: ...user should check the water temperature with an accurate thermometer A temperature of 38 C is considered safe for a healthy adult Special caution is suggested for young children 3 It is recommended t...

Page 11: ...ponents dry and protect them from continual damp conditions and will also aid you when draining the Spa for maintenance If you are installing your Spa indoors pay close attention to the flooring benea...

Page 12: ...should be clear of the pool surround no weight is to be taken by the rim Fill the bottom of the Spa pool with water to cover all plumbing outlets and check for water leaks rectify if necessary Empty w...

Page 13: ...major share of the weight The reclining area will be supported where it touches the horizontal support structure When you are satisfied the Spa pool will sit level and be firmly supported remove the S...

Page 14: ...the seat and reclining areas Constantly check the Spa pool for level when back filling Complete the Spa pool surround and plumbing Sloping Site Installation Brick Surround When installing your Spa poo...

Page 15: ...ion of switch Our In ground Spas are controlled via air switches buttons not by the electronic method mentioned in this manual for Portable Spas Blower installation The blower needs to be mounted a mi...

Page 16: ...ower 6 Ensure Spa is connected on a dedicated circuit protected by a safety switch Note to the Electrician Drill appropriate size hole through base for cable and conduit entry Ensure cables are fitted...

Page 17: ...ntrol System Power supply to the Spa needs to be on a dedicated circuit and be protected by a Residual Current Device Safety Switch as well as the correct size cable and circuit breaker protection In...

Page 18: ...service panels around the exterior of the Spa inspect for any item that may have come adrift or loosened during transport Leave doors off until Spa is filled with water and a check for l eaks has be...