E- To add a new badge (BADGES function)
1) Enter programming mode.
2) Enter
6 2 2
.
3) Enter the badge’s code (
0 0 1
for the first up to
5 0 0
)
4) Move the badge in front of the keypad.
5) Press
#
(to confirm).
6) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
0
.
F- To remove a badge and its user code
1) Enter programming mode.
2) Press
3
.
3) Enter the code of the badge to remove.
(Example:
0 0 1
).
G- To remove all the codes
1) Enter programming mode.
2) Press
4 4 4 4
(only the programming code is not deleted).
3) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
0
.
=> PROGRAMMING THE TYPE OF USING
1) Enter programming mode.
2) To choose :
- Key function: Press
6 2
+
#
(to confirm).
- Key OR code function:
6 0
+
#
.
- Key AND code function
6 1
+
#
.
3) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
0
.
=> PROGRAMMING THE OPENING TIME
To program the opening time of the door
1) Enter programming mode.
2) Press
5
plus the time required in seconds.
(Example
5 2 0
for 20 seconds of opening time).
3) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
0
.
=> ALARM PROGRAMMING
To enable the full alarm:
1) Enter programming mode
2) Press
8 1
. No programmed code can be used.
Press
8 0
to disable the alarm
3) If you want to continue the programming, move on directly to
another step. If you want to stop the programming, press
0
.
=> REMINDER : If you want to stop the programming, press
0
.
=> DOOR OPENING: Enter the code followed by
#
to confirm.
The door will open.
=> LOST PROGRAMMING CODE: If you forget your code, you
must switch off the current, open up the keypad and press «REST»
(function within the keypad). While pressing and holding REST,
power up the keypad and wait for 3 seconds.
Close the keypad and you can then begin the programming
operation again.
=> FALSE CODE: If you enter 8 successive false codes, the keypad
will lock automatically, and the alarm will be triggered.
The alarm will sound for 90 seconds.
5)WIRING DIAGRAM
Follow the instructions opposite to install the keypad.
1 2
3 4
5 6
7 8
9 0
#
Rouge
Noir
Jaune
Bleu
Blanc
Vert
Orange
Gris
Gris
+
+
-
-
Carillon
(contact sec)
Alarme
additionnelle
Bouton
de sortie
Serrure
électrique (12V)
(Contact NC)
ou (Contact NO)
Alimentation
Interrupteur
magnétique
de la porte
V
er
s NOIR
Vers NOIR
V
er
s NOIR
V
er
s NOIR
Automatisme (contact sec)
RED
BLACK
YELLOW
BLUE
WHITE
GREEN
ORANGE
GREY
GREY
Electric lock (12 V)
Power supply
(NC Contact)
(NO contact)
Automated system (dry contact)
Chime (dry
contact)
Additional
alarm
Door magnetic
switch
Exit button
To black
To black
To black
To black
ENGLISH