6
Rotary Switch Function:
Transmitter and receiver must setting at same channel in order to do mutual transmission.
Rotary switch to be follow 16 HEX, could switch
“
0 ~ F
“
total 16 channels, A = channel 10, B =
channel 11, others channel same as 16 hex conversion.
Transmitter channel setting must be unique to avoid conflict with any other transmitters.
After rotary switch change must reboot or power off/on the transmitter
Please refer Web Setting page to set transmitter by APP or web for over 16 channels
Panel Button Function:
ITEM
TRANSMITTER
Button
LINK
FUNCTION
Short Press
Remote output (
on
/ off)
Video Mode
/ Graphic Mode
Long Press (3 seconds)
Loop output (
on
/ off)
Anti-Dither (1/2/
off
)
Press to power on (Hold until
Green LED Flash)
N/A
Update EDID from loop output
Press to power on (Hold until
Green and Blue LED Flash
then manually reboot)
RESET to Default
N/A
Above
“
bold font
”
part as the default
ITEM
RECEIVER
Button
CH. -
CH. +
Press both
Confirm / Enter menu / Turn on video output
Short Press
Reduce the numbers of Channel/Menu/Value Increase the numbers of Channel/Menu/Value
Press for 1 second before
power on, or press for 5
seconds in using
(VDKM01BR only)
VGA output only
DVI output only
Press both for 5 seconds
(VDKM01BR only)
DVI and VGA output both
(DVI monitor must be connected and power on)
Above
“
bold font
”
part as the default
For HE05BER please use IR remote control or APP/PC Software for channel setting.
RJ45 pin define:
Link Cable (TIA/EIA-568-B)
1. Orange-white Data 1 + 5. Blue-white
Data 3 -
2. Orange
Data 1 - 6. Green
Data 2 -
3. Green-white
Data 2 + 7. Brown-white
Data 4 +
4. Blue
Data 3 + 8. Brown
Data 4
–