1. Introduction

This Meter is designed to meet IEC61010-1 & CAT III 600V over voltage
category . The meter with holster that is giving the main body, though
downsized, high resistance against the shock of a drop.
This operating instruction covers information on safety and caution.
The DMM as general measurement tool and widely used in the school,
laboratory, factory and other social field.

2. Safety note

Warning

To avoid possible electric shock or personal injury and to avoid possible
damage to the meter or to the equipment under test, adhere to the following
rule:

Do not apply more than the rated voltage, of marked on the meter,

between the input terminal and grounding terminal..

Do not apply voltage between COM and OHM terminal, in the

resistance measuring state.

Do not expose the instrument to the direct sun light, extreme

temperature and humidity or dew full.

Inspect the test lead for damaged insulation or exposed metal.

Before measuring current, check the Meter’s fuses and turn off

power to the circuit before connecting the meter to the circuit.

Disconnect circuit power and discharge all high voltage capacitors

before testing continuity, diode, resistance, capacitance or current.

Electrical Symbol:

CAT
III

Measurement category III is applica

ble to test and measuring circuits co

nnected to the distribution part of th

e building’s low voltage MAINS insta

llation

3.

Product illustration

Summary of Contents for 830A, 830B, 830D, 830C

Page 1: ...cification 4 1 General feature 4 2 Electrical specification 5 Measurement operation 5 1 DC voltage measurement 5 2 AC voltage measurement 5 3 Resistance measurement 5 4 Diode measurement 5 5 Continuit...

Page 2: ...voltage of marked on the meter between the input terminal and grounding terminal Do not apply voltage between COM and OHM terminal in the resistance measuring state Do not expose the instrument to the...

Page 3: ...o press it again note when the battery is insufficient the brightness of the backlight will not enough Operating temperature Humidity 0 40 32 104 75 RH Storage temperature Humidity 10 50 14 122 80 RH...

Page 4: ...acy 1 5 rdg 5dgt 1 5 rdg 5dgt 1 5 rdg 5dgt 1 5 rdg 5dgt DC Current Range 20 A 200 A 2mA 20m 200 mA 10A 20 A 200 A 2mA 20m 200m A 10A 20 A 200 A 2mA 20m 200mA 10A 200 A 2mA 20m 200mA 10A Accuracy 1 2 r...

Page 5: ...range switch at the highest range position and then reduce it until satisfactory resolution is obtained 3 Connect the test lead across with the object under testing The measured value will be show on...

Page 6: ...e is good the display shows 1 If diode is shorted the display shows 0 zero in both direction If display shows 1 in both direction the diode is open 5 5 Continuity Measurement 1 Turn the rotary switch...

Page 7: ...new fuse of the same size and rating 3 Replace the bottom case and install all the screw 6 2 Replacement battery When meter display the battery must be replace to maintain normal operation 1 Disconnec...

Reviews: