background image

P:\INSTALLATION INST\Access Controls\INST-917 QUICK REF\INST-917 QUICK REF.vsd     REV A     05-09    Page 1  

Any suggestions or comments to this instruction or 

product are welcome.  Please contact us through 

our website or email engineer@sdcsecurity.com 

SECURITY DOOR CONTROLS

3580 Willow Lane, Westlake Village, CA 91361-4921  •   (805) 494-0622  •  Fax: (805) 494-8861
www.sdcsecurity.com  •  E-mail: service@sdcsecurity.com

917 QUICK REFERENCE/WORKSHEET

NOTE: [ ] means press keys simultaneously

Factory Default Master Code is 1234 
Make all electrical hookups per drawings in Installation Instructions

Basic Programming:

1.  Enter program mode

2.  Program User code:

3.  Assign User to Main Relay 0:

4.  Set Main Relay time:

5.  Assign REX to Main Relay:

Addtional Programming

6.  Delete User:

7.  Change Master Code:

8.  Reset to factory default settings:

9.  Master Reset

BEWARE!  ERASES MEMORY

BEWARE!  ERASES MEMORY

Press 

[*1]

Master Code

*

Press 

[*1]

Master Code 

[*2]

User Number

PIN Code

PIN Code

*

Press 

[*1]

Master Code 

[*0]

User Number

# 0  *

Press 

[*1]

Master Code 

[*3]

User Number of seconds

# 0 *

Press 

[*1]

Master Code 

[*4]

0 * 

Press 

*

red

 LED will turn on

Touch wire on Pin 10 (GRY/BLK) to wire on Pin 12 (ORG/BLK)

yellow

 LED will turn on.

Release wires.  After 2-3 seconds the 

green

 LED will turn on.

Default Master Code is 1234

User Number from 2-120.  PIN code up to 6 digits

Users can be assigned to Relay 0, & outputs 1-3

Time (1-225 sec.)

REX can be assigned to Relays 0, & outputs 1-3

Press 

[*1]

Master Code 

[*2]

User Number 

# * *

Press 

[*1]

Old Master

[*2]

1

#

New Master

New Master

Press 

[*1]

Master Code 

* Press 

[*9] 

*

Code

Code

Code

Deletes user

Master code is User 1

Erases memory

Erases all memory & returns to factory
default  Master code of 1234.

Note:

If you make an input error before entering *: wait 5 seconds and the command memory will be cleared automatically (or press # to clear manually). Start again.
Five operating errors within 60 seconds will trigger the Auto Lockout function which disables the keypad for 4 minutes and 15 seconds (255 seconds).

Remember the new Master code.

Summary of Contents for 917 EntryCheck

Page 1: ...de Press 1 Master Code 2 User Number PIN Code PIN Code Press 1 Master Code 0 User Number 0 Press 1 Master Code 3 User Number of seconds 0 Press 1 Master Code 4 0 Press red LED will turn on Touch wire on Pin 10 GRY BLK to wire on Pin 12 ORG BLK yellow LED will turn on Release wires After 2 3 seconds the green LED will turn on Default Master Code is 1234 User Number from 2 120 PIN code up to 6 digit...

Page 2: ...V A 05 09 Page 2 Programming 1 1 1234 2 11 1493 1493 2 1 1234 0 11 0 1 1 1234 3 3 0 1 1 1234 4 0 Enters Programming Mode Assigns User 11 the PIN code of 1493 Master code is 1234 1 means and 1 keys pressed simultaneously Action Enters Programming Mode Assigns User 11 PIN 1493 to Main Relay 0 Enters Programming Mode Main Relay Timer 0 set for 3 second unlock time Enters Programming Mode Assign REX t...

Page 3: ...red LED will indicate an error or the green LED will show that no error was detected The keypad will resume normal operation once the red or green LED status has been displayed Using This Manual First brackets and spaces are not part of the codes They are used here to clarify the operations and group like functions Square brackets are used to indicate that the keys inside the brackets are to be pr...

Page 4: ...y Toggle 5 sec Timer Out1 Toggle 15 sec Timer Out2 Toggle 25 sec Timer Out3 Toggle 35 sec Timer KeypadActive 7 msec pulse 10 sec To change an output time First enter program mode see first step Enter 3 then the time 0 255 seconds followed by then the output 0 6 followed by For example 3 3 0 0 will assign a time of 30 seconds to Output 0 Please note that you may change only one output timer at a ti...

Page 5: ...y First enter program mode see first step Enter 0 then UID code followed by then desired Outputs 0 to 3 followed by For example 0 1 0 9 0 2 3 will assign Outputs 0 2 and 3 to User 109 0 6 4 will assign assign no outputs to User 64 Troubleshooting Tips If you make an input error e g if you enter a non existent User Code and press the star key the red LED will light Simply start over Do not make the...

Page 6: ...ll stud and NOT flush with the sheetrock It is RECOMMENDED that all new installations be mounted in a standard plastic single gang box External Device Current Limits The SINK capability of 500mA applies to 12V AC DC or REGULATED 24VDC power and jumper J6 installed For unregulated 24VDC or AC supplies derate the SINK current to 50mA and REMOVE jumper J6 J2 J6 J1 1 U2 U3 U1 RELAY 1 NC 1 J4 C NO 1 J5...

Page 7: ...ire Size for J1 16AWG General Keypad Limits Remote Trigger minimum ON time 100ms Keypad Debounce time 100ms Keypad life 1 000 000 operations per key User Memory write cycle limit 1 000 000 cycles User Memory retension 40 years Applications Storage closets Machinery Controls Residential Commercial Doors Self Storage Facilities Multi Tenant Buildings Pools Saunas Recreation Centers Restaurant Freeze...

Reviews: