background image

The 

EntryCheck

™  920 Indoor/Outdoor Keypad is a surface-mount digital 

keyless entry system designed for access control applications.  The backlit 
keys  are bright and easy-to-read. A heavy cast vandal resistant housing 
design with mounting plate allows the 920  to be mounted on a  rugged 
surface or on a standard single-gang electrical box.  

The 920 has a capacity of 500 users. Users can be assigned to use 4 to 6 
digit PIN codes. An authenticated access  can be programmed to activate 
one or both of the onboard relay outputs. 

The timed “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has  elapsed.

Two long lasting solid state LED indicators show the status of the system.  
The left bi-color indicator lights red to indicate power, then solid green when 
a relay is active (access grant, etc.).  The right indicator flashes yellow to 
indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured  two ways through programming .  

When configured for “Door Sense”, the input is wired to a normally closed 
door position switch to detect when the door is opened or closed.  Forced 
entry or door ajar situations can then be detected. The “Auto-relock” feature 
can also be used  to  turn off the Main Relay output immediately when the 
door is closed after access has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired to 

a normally open “service” switch or automatic timer that will disable access 
while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open pushbutton 

to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3 
or Output #4 (user programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs  to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 920 

EntryCheck

™ is powered from a 12-24V AC or DC source. The 

non-volatile EEPROM memory retains  entry codes and programming when 
power is removed.  An internal jumper is provided to reset the master code.  
The Main Relay has a 5 Amp capacity.  The Auxiliary Relay has a 2 Amp 
capacity.  Two solid state outputs, capable of sinking 100 mA to common 
are programmable for alarm shunting, or to signal forced entry, door ajar, 
keypad lockout, request-to-exit, and keypad active conditions.

P:\INSTALLATION INST\Access Controls\INST-920\INST-920.vsd     Rev C     10-14     Page 1

INSTALLATION INSTRUCTIONS

920 

EntryCheck 

TM

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: service@sdcsecurity.com

SPECIFICATIONS

Mechanical

Dimensions: 3.00" W x 5.75" H x 1.375" D

(1.4375” wall projection)

Electrical

Input Voltage: 12-24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

Main Relay: Form “C” 5 Amps @ 28 Volts max

Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max

Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -22°F to 149°F (-30°C to 65°C)
Humidity: 5% to 95% non-condensing

FEATURES

Keypad programmable
500 user codes
4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or 
two relays
Disable input
Door sense input
Request-to-exit/Reception input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
12V or 24V, AC or DC operation

Summary of Contents for 920 EntryCheck

Page 1: ...o provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activ...

Page 2: ...correctly or the function is rejected If a red indicator is seen the entire function option code data will have to be fully re entered The keypad will remain in programming mode until is pressed or af...

Page 3: ...two wires from the switch to the keypad Connect the door switch to the keypad s SENSE wire gray E8 and COM wire any black wire Inhibit Disable access If an inhibit switch or timer is going to be used...

Page 4: ...ay 2 toggled The yellow indicator will flash quickly while the 920 stores the new user information in memory The green indicator will light when the new code is accepted If the user number already exi...

Page 5: ...activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 13 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Outpu...

Page 6: ...uring Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length...

Page 7: ...T Access Controls INST 920 INST 920 vsd Rev C 10 14 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Page 8: ...P INSTALLATION INST Access Controls INST 920 INST 920 vsd Rev C 10 14 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Reviews: