Fit remaining spindle to inside - non code side.
Step 9
Apply the front and back plates, with the neoprene seals in position, against the door, over the protruding
ends of the spindle.
Step 10
Fix the two plates together using the socket head bolts, starting with the top fixings. Ensure that the two
plates are truly vertical and then tighten the bolts using the ‘T’ shaped Allen key. Do not use excessive force.
Step 11
Check that the lever handles are correctly fitted for the hand of door. To change the hand of a lever handle,
loosen the grub screw with the small Allen key, reverse the lever handle and fully tighten the grub screw.
Step 12
Before closing the door, enter the code and check that the latchbolt will retract when the lever handle is
depressed. Now check the operation of the inside lever handle. If there is any binding of the handles or the
latch then loosen the bolts and reposition the plates slightly until the correct position is found, and then re-
tighten the bolts.
Step 13
Fit the double Euro-profile cylinder and secure it with the long screw through the faceplate. Fit the cylinder
escutcheons.
Step 14
Check that the deadbolt will project and retract by key, and that the key will also retract the latchbolt. Check
that the inside lever handle WILL retract the deadbolt simultaneously with the latchbolt. Check that the
outside lever handle WILL NOT retract the deadbolt.
Step 15
Mark a vertical line on the door jamb half the door thickness away from the door stop. This gives the centre
line of the strike plate. Align the Strike Plate Template with the height line, with the arrow heads aligned with
the centre line. Mark the fixing holes, and draw around the apertures for the latchbolt and the deadbolt.
Chisel out the latch aperture to 12mm ( ⁄ ”) deep, and the deadbolt aperture to 22mm ( ⁄ ”) deep. Fix the
strike plate with the top screw only and gently close the door. Ensure that the latchbolt enters its aperture
easily and holds the door without too much ‘play’. When satisfied, draw around the final position of the
strike plate, remove it, and cut a rebate to allow it to fit flush to the surface. Re-fix the strike with both
screws.