P:\INSTALLATION INST\ACCESS CONTROLS\E75\INST-E75.vsd     REV F     03-20     Page 4

Quick Start

Programming Instructions

E75 

EntryCheck 

TM

Test the Lock Operation

To test lock operation before initialization,  enter  

*741

.  This temporary code will unlock the E75 for testing purposes. 

Once a lock initialization has been performed, this code is no longer active until a hardware reset is performed which 
will erase  all the users and return  the E75 back into the uninitialized factory default condition. 

Prox Units

Only

User Programming

Add a User PIN Code (4-6 digits):  

01# User No.# PIN Code # Pin Code # Group No.#

Example: 

Press  01#           04#            5050#            5050#           06#

You have just added User #04 with a PIN of 5050 to unlock the door.
User 4 has been assigned to group 06 (24/7 access).

To Initialize Lock:

Press #9* 123456# 0001#

The above example enters a Lock ID of 0001. If multiple locks are used it is recommended that each lock 
have its own 

Unique

Lock ID (0002, 0003, etc.).  This is required when using the E7 Management Software.

Lock Initialization

When the lock is first installed or after a factory reset has been performed, the E75 must be initialized with a 4-digit 
lock ID  before you will be allowed to enter programming mode.

NOTE:  You must first enter programming mode to perform any other function.  20 seconds of inactivity will 
automatically exit you from programming mode and return you to operational  mode.

Test the lock by pressing 5050#, or present a valid prox card to the reader (prox units only).

Add a Sequential Batch of Cards:  

08# Starting User No.#  No. of Cards# Present 1

st

Sequential Card

Example: 

Press  08#           05#           10#           Present Card

You have just added (10) proximity card for User #’s 05 to 14.
All users has also be assigned to group 06 (24/7 access).

Add a Single Card:  

06# User No.#  Present Card

Example: 

Press  06#           04#           Present Card

You have just added a card to User #4.
User 4 has also be assigned to group 06 (24/7 access).

Exit Programming Mode:  **#

Press **#

Enter Programming Mode:

Press #9# 01# 123456# 

User 01 with default PIN Code 123456 is the administrator and has full programming rights.

For a complete list of lock programming functions, including programming for the E75KL/E75PL Privacy Lock, refer to 
the E75 Programming Guide included with this lock.