FACTORY DEFAULTS

Master Programming Code………..………………..….…...123456  
Keypad Output Mode……………………...……..…26-bit Wiegand
Keypad Output Site Code……………………………………..…000
Beeper Sounds When Key Pressed……….…………...………Yes
Beeper Volume……………………………………….….……Normal
Keypad Backlight Mode…………………..…30 sec after activation
Keypad Timeout………………………………..………..………5 sec

918W OPERATION

The 918W EntryCheck™ keypad will emulate a reader credential.  
Entering a ‘card’ number followed by ‘#” will transmit the 
programmed facility code plus the card number as a 26-bit 
Wiegand output.  The card number entered must be > 0 and < 
65,535.

For example, if the default Facility Code has been changed to 
123, pressing 1234 + #, will send ‘12301234’ as the complete 
card number. 

Entering Programming Mode

  

The 6-digit Master Programming Code (default = 123456) is 
used to enter Programming Mode.

Press:  # 9 # Master Code #

Master Code = the current 6-digit Master Programming Code

BASIC PROGRAMMING

While the 918W is in Programming Mode the yellow indicator 
will blink slowly.

After a programming function is selected, the yellow indicator 
will flash rapidly while the keypad is waiting for user input data.  
You will have 5 sec. between programming commands once a 
function is selected.  The green indicator will light if the data is 
accepted.  The red indicator will light if any programming data 
is entered incorrectly, and the function will have to be fully re-
entered.

Exiting Programming Mode

Press:       

 

The red indicator will light after exiting Programming Mode

Note: 

 The 918W will automatically exit Programming Mode after 

2 minutes of inactivity

**

Changing the 6-Digit Master Programming Code

 It is recommended that the Master Programming Code be 
changed after the installation is finalized. 

Press: 98 # 

Master

 

Code

 

 # 

Master Code

 

 #  

Master Code = The new 6-digit Master Programming Code

Changing the

 

Beeper Sound Level

The Keypad’s beeper can be set to normal or low level.
Remove jumper JP1 to reduce beeper sound level.  
See Page 2 for the location of JP1.

PROGRAMMING FUNCTIONS

Enter Programming Mode before performing any of the following 
functions.

Beep Sounds on Keystrokes                                  Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

 

 #  

Sound=1 for Yes, =0 for No

Selects mode for Keypad LED Backlight       Default: 30 Secs.

Selects whether or not the keypad back light stays OFF, lights for 
30 seconds when activated or stays ON.

Press: 52 # Output

 

 #  

Output = 0, Light always OFF
            = 1, 30 sec light when activated (default)
            = 2, Light always ON 

Change Facility (Site) Code                                    Default:  000

Selects the Site Code when using the Keypad in Weigand Mode.

Press: 82 # 

Site Code

 

 #  

Site Code = New 3-Digit Site Code (000-255)

Master Reset

Resets all programming options.  

NOTE

: The Master Code will NOT be reset.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys 
down until the red indicator starts flashing

STEP 4

Release the keys.  The red and yellow indicators will 
remain lit until the process is complete, then the yellow 
indicator will go out.

Resetting the Master Code

STEP 1

Remove the 918W from the wall and disconnect 

power from the keypad.

STEP 2 

Locate & remove jumper JP2.  Reference page 2.  

STEP 3

Re-apply power.  You will get a single beep and 
the yellow LED will flash momentarily.

STEP 4

Replace jumper on JP2.  The Master Code is now 
123456.

RESETTING THE KEYPAD READER

ERROR ANNUNCIATION (Wiegand Mode only)

Keypad Action

Indication

Key press timeout (in standby)

Double Beep

0, or number >=  65535 is entered Red LED flash w/ beep (x3)
* is entered

Red LED flash w/ beep (x3)

Master Code error

Red LED flash w/ beep (x3)