P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd     Rev F     05-19     Page 2

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

Test  your new user

Enter PIN code ‘2580#’. The green indicator should illuminate and the main relay 
should activate, unlocking  the door for 5 seconds.

Assign a user code

Step 1. Enter:  

#9#  123456#    

Enter the program mode (default master code)

Step 2. Enter:  

01#  002# 2580# 2580# 1#    

Assign User 002 with a PIN code of ‘2580’. 

Activate  the main relay when entered.   

Step 3. Enter:  

#  

Exit programming mode

Deleting a  user code

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

02#  002# 002# 

User  2 has been deleted. 

Step 3. Enter:  

#  

Exit programming mode

Adding additional user codes

Once the code length and relay time has been set  you do not need to set them again for 
additional users.

To add additional users:

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

01#  003# 2222# 2222# 1# 

User 003 has been created with a PIN code of 

‘2222#’ to activate  the main relay 

Step 3. Repeat Step 2 to enter another unique User # & PIN code OR skip to Step 4.

Step 4. Enter:  

#  

Exit programming mode

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“PROGRAM”
INDICATOR

KEYPAD

FRONT

Set default parameters (first time use)

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter: 

03#  4# 

Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

Set the main relay activation time for 5 sec.

Step 4. Enter:  

#  

Exit programming mode

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 923 
EntryCheck™ is in programming mode. Use the option codes to program each function.   After the new data entry is complete for 
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the 
programming has been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is rejected. 
If a red indicator is seen, the entire function (option code + data)  will have to be fully re-entered.The keypad will remain in 
programming mode until        # is pressed or after 30 seconds of inactivity.

BLACK

PINK/SALMON

GREEN

GRAY

BLACK

VIOLET

BLACK

BLUE

DOOR POSITION 

SWITCH

[N/C]

REQUEST-TO-EXIT 

SWITCH

[N/O]

GROUND

OUTPUT #4

OUTPUT #3

GROUND

SENSE

REQUEST TO EXIT

GROUND

E1

E8

E7

E6

E5

E4

E3

E2

C

NO

C

NC

NO

AUXILIARY OUTPUTS

100mA MAX TO COMMON

{

*

*

NOT USED

NC

TO POWER SUPPLY

KEYPAD POWER

12 or 24 VOLTS

AC OR DC

}

+

-

RED

BLACK

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

}

NO

COM

ORANGE

WHITE

BLACK

MAIN RELAY

5 AMPS @ 28VDC MAX

}

NO

COM

NC

ORANGE

WH

ITE

YE

L

LO

W

POWER

WIRE
HARNESS
(E1-E8)

ANTI-TAMPER

SWITCH

AUXILIARY
RELAY

BACK

JP1

MAIN
RELAY

JP2

Grn Wire
To earth ground

Fig. 2 Wiring Pigtail Color Code

Summary of Contents for EntryCheck 923

Page 1: ...ill prevent tailgating by turning off the Main Relay output immediately when the door is closed after access has been granted If the SENSE input is programmed for inhibit the input can be wired to a service switch or automatic timer that will disable the Main Relay when required The REQUEST TO EXIT input can be wired to a pushbutton to provide codeless activation of Main Relay Auxiliary Relay Outp...

Page 2: ...56 Enter the program mode default master code Step 2 Enter 03 4 Set the entry code length to 4 digits Step 3 Enter 21 5 Set the main relay activation time for 5 sec Step 4 Enter Exit programming mode QuickStart Programming You must first enter programming mode to perform any function The yellow indicator will blink slowly showing that the 923 EntryCheck is in programming mode Use the option codes ...

Page 3: ...es this unit must be connected to a proper earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as either a door sense or inhibit input Both features cannot be used at the same time If you are not using the sense input program this input for inhibit Door Sens...

Page 4: ...ation in memory The green indicator will light when the new user is accepted If the user number already exists or an entry error has been made the red indicator will light Delete the user and re enter the new information again Note Leading zeros zeros before the Code number i e 0001 do not need to be entered when programming a new code The 923 will internally add any zeros to fill digits determine...

Page 5: ... No Output Select Keypad Lockout Output Default No Output Sets which output activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 1 3 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Output 3 4 Output 4 0 No Output Select Alarm Shunt Output Default No Output Sets which output activates during the time access i...

Page 6: ... Locate Remove jumper at JP2 Reference page 2 STEP 3 Re apply power You will get a single beep and the yellow LED will flash momentarily STEP 4 Replace jumper on JP2 THE MASTER PROGRAMMING CODE IS NOW 123456 Beep Sounds During Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 4 1 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 S...

Page 7: ...P INSTALLATION INST Access Controls INST 923 INST 923 vsd Rev F 05 19 Page 7 4X Mount at holes With supplied screws and hole expansion anchors 1 375 7 3125 1 750 WALL MOUNT MULLION MOUNT ...

Reviews: