E1200
MAGNETIC LOCK
Use properly fused U. L. Listed Power Supply
Do not install a diode in parallel with any magnetic lock. A diode
will cause a delay when releasing the door and residual magnetism
to occur.
Although SDC recommends the use of a DC power supply, a
transformer with an adjacent mounted full wave bridge rectifier may
be used. A significant drop will occur when using a full wave
bridge rectifier.
Any low voltage condition will cause erratic operation of the
optional board sensor.
When using a full wave bridge rectifier all access controls and/or
release contacts must be located between the EMlock and rectifier
to ensure quick release.
Dual Voltage:
Power Consumption:
DS Door Status Sensor:
LS Lock Status Sensor:
Outswing
Quick Mount
Interlocking
Mounting Assembly
Mounting Screws
Armature
Interlocking
Mounting Plate
Frame
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INST INSTRUCTIONSRUCTIONS
Electrical Instructions:
Electrical Specifications:
12 or 24VDC
.505mA @ 12VDC
.260mA @ 24VDC
SPDT, 500mA @ 30VDC
SPDT, 2A @ 30VDC