3.0    CONSOLE WIRING EXAMPLES

3.4

Installation Procedure

Step 1 

– Select appropriate wiring diagram

.Fig. 6, 7, or 8 to wire the console direct to door locking devices or via relay modules.

Step 2 

– Wire External Relay modules.

If used configure and wire external relay modules, such as SDC

’s UR-1 or UR4-8 (see applicable installation manual)

Step 3 

– Terminate the Lock Power / Control Wiring (Switch Outputs 1-4). 

 

Determine whether the switch outputs will be used to switch lock power directly or as dry signal outputs to auxiliary relay boards.  
Follow the wiring diagram appropriately for fail-safe or fail-secure locks.  Be careful to observe lock voltage polarity.  NOTE:  All low 
voltage lock wiring shall be 18-gauge minimum (wire gauge shall be determined by the SDC wire gauge chart or another voltage drop 
too).  Signal wire shall be 22-gauge minimum.

Step 4 

– Terminate the Door Monitoring (Optional LED Inputs)

Connect the Door Position Status switches, Latch Status switches to the LED inputs directly or via secondary relays, per the 
appropriate wiring diagram.

Step 5 

– Terminate Key Switch / Reset Outputs (Optional)

A1, A2, A3 Output 

– This SPDT output is controlled by either the Key Switch or the momentary Reset button which connect to the I/O 

board at input J8.  Refer to section 2.1.2 on Page 9 for more information.

Step 6 

– Connect 24VDC Power Source to the Power inputs.

Before applying power, verify that all the connections are securely terminated by gently pulling on each wire.  Connect 24VDC  power 
to the I/O board Power Input, as shown in the wiring diagram.  Be careful to observe polarity.

Step 7 

– Verify Operation

Test operation of door locking devices and LED

’s by pressing each rocker switch.  If applicable, verify operation of LED’s and alarm 

buzzer, by opening each door without pushing a button, causing a forced door alarm.  Verify operation of Audible Shunt button by 
pressing it to silence the forced door alarm.  Test operation of Key Switch and Reset Button if connected.

Summary of Contents for RCC Series

Page 1: ...NTROL CONSOLES INST TCC RCC REV D 10 20 Page 1 Any suggestions or comments to this instruction or product are welcome Please contact us through our website or email engineer sdcsecurity com TCC RCC Se...

Page 2: ...P INST INSTRUCTIONS CONTROL CONSOLES INST TCC RCC REV 10 20 Page 2 Intentionally left blank...

Page 3: ...itch Outputs 2 1 2 Reset Button Key Lock Switch Output 2 1 3 LED Alarm Power 2 1 4 Control Inputs 3 0 3 1 Direct Connection to Locking Devices with 2 State Status LED Door Closed for AL or BL Series P...

Page 4: ...P INST INSTRUCTIONS CONTROL CONSOLES INST TCC RCC REV 10 20 Page 4 Intentionally left blank...

Page 5: ...Series Consoles consist of an enclosure switches LEDs and terminal connector An audible alarm beeper is provided with E type switch panels containing the Alarm Shunt Reset Button and Key The Consoles...

Page 6: ...um when using 2 switch panels Base unit less switch panels See Page 6 for panel configurations Switch Panels All Models Switch Type Switch LED Count Rocker Switch Rating DRY Rocker Switch Output 2 or...

Page 7: ...3 position Type D Momentary OFF Momentary Switches 3 position Closed Open Latched Open Closed Activated Latched until pressed back to Normal Normal Standby Terminal Configuration Terminal Configurati...

Page 8: ...ion Part No Description Image AL4 Four Momentary Switches with LED s BL4 Four Maintained Switches with LED s CL4 Four Momentary Off Maintained Switches with LED s DL4 Four Momentary Off Momentary Swit...

Page 9: ...boards the numbers the switch Fig 3 TCC Interior View TCC x AL4 x EA shown Reset Switch Pre wired Switches Knockout for Field wiring Audible Shunt Key Lock Switch Reset Audible Shunt and Key Lock onl...

Page 10: ...J8 Reset Button or Key Switch one per I O board J9 Audible Shunt Switch Note When using multiple I O boards the audible shunt switch may plug into any J9 connector To utilize both the reset button an...

Page 11: ...d Terminal Reset Button Inactive Reset Button Pressed Key Lock Switch Key Horizontal Key Lock Switch Key Vertical A1 A2 A3 Common Closed Open Common Open Closed Common Closed Open Common Open Closed 2...

Page 12: ...y completing the circuit or for a fail safe device it breaks the circuit When a DC power source is applied to the PWR input all return RTN outputs on the console I O boards are supplied with 24VDC The...

Page 13: ...C These outputs may be used to power the red green or yellow indicator LED s on the console When wired per the circuit diagram in Figure 7 the amber LED illuminates while the door is unlocked opened b...

Page 14: ...am in Figure 8 the Green LED illuminates when the door is closed and locked To indicate an authorized unlock or forced door status set the UR 1 for CR or TD operation refer to UR 1 manual wire the red...

Page 15: ...erminate the Door Monitoring Optional LED Inputs Connect the Door Position Status switches Latch Status switches to the LED inputs directly or via secondary relays per the appropriate wiring diagram S...

Page 16: ...check the RCC TCC I O board for loose connections by carefully on all screw terminal connections Check wiring at door for switch continuity and or voltage If connected to doors via external relay modu...

Reviews: