S6000-101 Series – Operational Description

The door is normally closed and secured by the S6000-101 Delayed Egress Exit Device. The on-board status LED 
illuminates Green indicating that the unit is secured.  The integral Reset/Bypass key switch is in the center position.

Activation/Alarmed Release

:

Pressing the push pad of the S6000-101 device initiates the irreversible 15 second 

unlock delay cycle. To prevent false alarms, a pre-alarm audible warning tone is activated during the short nuisance 
delay period.  Releasing the push pad during the nuisance delay period will silence the pre-activation warning tone,  
reset the unlock delay cycle, and keep the door locked.   

Once the nuisance delay period has been exceeded, the S6000-101 continues its irreversible door release cycle.  An 
audible tone and Yellow status LED inform the person intending to exit of the door release cycle activation.  An alarm 
output is activated to alert personnel of an unauthorized exit. After the delay cycle has expired, the status LED 
illuminates Red, and power is removed from the locking device, allowing free egress by pressing the push pad. A second 
output is activated indicating that the door is unsecure.

Reset/Relock (from an Alarm, REX, or Bypass state):  

The S6000-101 can be manually reset by authorized 

personnel by closing the door and turning the integral key switch to the reset position, or by momentarily activating a N/O 
switch connected to the remote Reset/REX control input.  

Request-to-Exit (from a Secure state):  

A timed Request-to-Exit (REX) cycle is initiated by authorized personnel by 

momentarily turning the integral key switch to the reset position, or by momentarily activating a N/O switch connected to 
the remote Reset/REX control input. The power will be removed from the locking device allowing free egress by pressing 
the push pad. The on-board status LED will rapidly flash Green (2x / sec) during the REX cycle.  After the REX cycle has 
expired, the S6000-101 will automatically re-apply power to the locking device to re-secure the door.  If an external door 
position switch is connected to the DPS input, the door will automatically relock on door closure.

Authorized Maintained Bypass (from a Secure state):  

Unlocking the door for an extended period of time is 

accomplished by momentarily turning the integral key switch to the Bypass position, or by momentarily activating a N/O 
switch connected to the remote Bypass control input. The power will be removed from the locking device allowing free 
egress by pressing the push pad. The on-board status LED will slowly flash Green (1x / sec) during Bypass mode. The 
S6000-101 may be re-secured using the Reset procedure described above.

(BOCA/Chicago)

The S6000-101 operation complies 
with BOCA National Building Code 
and the Chicago Building Code:  UL 
Listed, Special Locking Arrangements 
and Auxiliary Locks.

Option 

Code 

Delay Release 

Time

Nusiance 

Time

Reset after 

Alarm

Lock Status on 

Power-Up

Auto/Manual

BD

15 sec

Fixed

1 sec or 2 sec

Selectable

Locked or Unlocked

Selectable

Auto/Manual

BH

30 sec 

Fixed

1 sec or 2 sec 

Selectable

Locked or Unlocked

Selectable

Auto/Manual

BC

15 sec

Fixed

0 sec 

Fixed

Locked or Unlocked

Selectable

Per BOCA compliance, the S6000-101 is manually reset by authorized personnel after an alarm by closing the door and 
turning the integral key switch to the reset position, or by momentarily closing a contact connected to the remote Reset/
Bypass control inputs. In addition, a reset will be automatically be initiated once the door has been opened, then closed, 
and remains closed for 30 consecutive seconds. 

(NFPA-101)

The S6000-101 operation complies 
with the following building and fire 
codes:  NFPA 101; NFPA 1-UFC; 
UBC; IBC; IFC; SBC; California 
Building Code.  Listings: UL Listed: 
Special Locking Arrangements and 
Auxiliary Locks; California State Fire 
Marshal (CSFM) Listed.

Option 

Code 

Delay Release 

Time

Nusiance 

Time

Reset after 

Alarm

Lock Status on 

Power-Up

Manual

ND

15 sec 

Fixed

1 sec or 2 sec

Selectable

Locked or Unlocked

Selectable

Manual

NH

30 sec

Fixed

1 sec or 2 sec

Selectable

Locked or Unlocked

Selectable

Manual

15 sec

Fixed

1 sec or 2 sec

Selectable

Unlocked

Fixed

NC

(CBC Compliant)

P:\INSTALLATION INST\Delayed Egress\INST-S6000-101.vsd      Rev D.1    10-19     Page 2

(AHJ Approval)

(AHJ Approval)

Summary of Contents for S6000-101

Page 1: ...with AHJ approval Control Inputs Field selectable 1 to 30 second request to exit with anti tailgate and door prop alarm Bypass Reset Remote trigger for Pairs of Doors DPS Required for Door Forced Prop...

Page 2: ...or If an external door position switch is connected to the DPS input the door will automatically relock on door closure Authorized Maintained Bypass from a Secure state Unlocking the door for an exten...

Page 3: ...Single Door Pair of Doors WARNING CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL PRIOR TO SELECTING NUSIANCE TIME OR PWR UP SETTINGS DIP SWITCH SETTINGS 1s 2s 15s 20s 30s 1s ON ON OFF 1 2 3 4...

Page 4: ...ormally Open OR Normally Closed using Jumper J7 The YELLOW wire is the relay common Green Green Relay This is the Door Secure Relay Output Dry 1A 12 24VDC It is normally ACTIVE when the door is secure...

Page 5: ...on KEY CYLINDER INSTALLATION OPERATION Key cylinder is in the normal center position LED is solid green when the device is secure To bypass the device for an extended period of time momentarily turn t...

Page 6: ...ONTROL SYSTEM C N C N O Installation Note Cap any unused leads MOV TYPICAL WIRING FOR SINGLE DOOR WITH SDC ELECTRIC TRIM SDC S6000 101 Install MOV across coil to protect device electronics J6 GRN RELA...

Page 7: ...ON INST Delayed Egress INST S6000 101 vsd Rev D 1 10 19 Page 7 1 Install Key Cylinder as shown and secure with locking nut provided 2 Remove and position Tailpiece as shown ILCO equivalent tail pieces...

Reviews: