P:\INSTALLATION INST\Delayed Egress\INST-S6000-101.vsd Rev D.1 10-19 Page 6
BLU (Reset/REX)
WHT (Bypass)
RED (+)
BLK (-)
Power
Transfer
24
V
D
C
YEL (Rly – COM)
SDC 600 Series
REGULATED & FILTERED
POWERSUPPLY
GRN
BRN
MASTER
MC-4**
Door
Contact
GRN
WHT
GRY
(DPS)
**Door Contact connection MC-4 is provided with
every Master Unit. Use for anti-tailgate, BOCA,
door prop alarms and added security.
ORG
VIO
NOTE
: 24VDC VOLTAGE CONFIGURATION W/ NO OPTIONS
4' - Conductor Cable
standard
24vdc @ .3 AMP
RED (+)
BLK
BLU
WHT (-)
SDC ELECTRIC TRIM
EKE03/GKE03 SERIES
ACCESS
CONTROL
SYSTEM
C
N/C
N/O
Installation Note: Cap any unused leads.
+
(
‐
)
MOV
*
TYPICAL WIRING FOR SINGLE DOOR WITH SDC ELECTRIC TRIM
SDC S6000-101
*Install MOV across
coil to protect device
electronics.
J6 = GRN RELAY (Active when device is secure)
2 Left Pins = Set for Fail-Secure Electric Trim
2 Right Pins = Set for Fail-Safe Electric Trim
NOTE: SDC Electric Trim not available for S6300 Mortise Device
STATUS LED INDICATIONS
Status
Device
Mode
OFF
No
Power
GREEN
(Solid)
Secure
YELLOW
Irreversible
Delay
in
Progress
RED
(Solid)
Alarmed
&
Unlocked
GREEN
(Slow
Flash) Bypassed
GREEN
(Fast
Flash)
Authorized
Unlock
(REX)
RED
(Fast
Flash)
Alarmed,
Unlocked,
&
Door
Opened
ELELCTRIC TRIM WIRES
MUST BE
WIRED THRU THE
DOOR RACEWAY NOT
THROUGH THE EXIT DEVICE