background image

SDE Lighting – 

www.sdelighting.com

 – Sixty Scan 

 

SDE Lighting Sixty Scan 

1.

 

GETTING STARTED 

What’s In The Box? 

 

SDE Lighting Sixty Scan 

 

5ft IEC power cable 

 

User Manual  

Congratulations on your purchase of the future of lighting! 

Now that you have a Sixty Scan you should carefully unpack the box and 
check the contents to ensure that all pieces are present and in good 

condition. If anything looks as if it has been damaged in transit, notify the 
shipper immediately and keep the packing material for inspection. 

 
Powering Up 

All fixtures must be powered directly from a switched circuit and cannot be 
run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat 
or dimmer channel is used solely for a 0% to 100% switch. 

All fixtures must be connected to circuits with a working Ground. 
 

SAFETY PRECAUTIONS 

• ALWAYS make sure that you are connecting to the proper voltage. 

• This product is intended for indoor use only. To prevent risk of fire or 
shock, do not expose fixture to rain or moisture. 

• Make sure there are no flammable materials close to the unit while 
operating. 

• ALWAYS disconnect from the power source before replacing fuse and be 
sure to replace with same fuse size and type. 

• ALWAYS secure fixture using a safety chain. NEVER carry the fixture by its 
cord. Use its carrying handles. 
• DO NOT operate at ambient temperatures higher than 113°F (45°C). 

• In the event of a serious operating problem, stop using the unit 
immediately. NEVER try to repair the unit by yourself.  

• NEVER connect the device to a dimmer pack. 
• Avoid direct eye exposure to the light source while it is on. 

ATTENTION 

There are no user serviceable parts in the unit. Do not open 

the housing or attempt any repairs yourself. In the event your unit may 

require service, please contact SDE Lighting at 

support@sdelighting.com

. 

 

Fuse Replacement 

With a flat head screwdriver, wedge the fuse holder out of its housing. 

Remove the blown fuse from its holder and replace with exact same type 
fuse. Insert the fuse holder back in its place and reconnect power. 
 

Summary of Contents for Sixty Scan

Page 1: ...door use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating ALWAYS disconnect from the power source before replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate a...

Page 2: ...32 fixtures may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 1640 ft The maximum recommended number of fixtures on a single link is 32 To link fixtures together you ll need DMX cables You should always use data grade cables that can carry a high quality signal and are less prone to interference Standard microphone XLR cables will work but are not ...

Page 3: ... d 2 for slow room scan d 3 for use with a remote sold separately The master unit must be the first unit Finally chain the units together using DMX cable 3 Select slave units by using the UP DOWN keys to reach S 1 in the Slave menu for identical movement S 2 for reverse pan S 3 for reverse pan and tilt S 4 for reverse tilt and they will react with the Master DMX Mode The Sixty Scan will automatica...

Page 4: ...s DMX Channels Channel 1 Pan Horizontal Movement Value 0 255 128 Center Gradual mirror adjustment from left to right Channel 2 Tilt Vertical Movement Value 0 255 128 Center Gradual mirror adjustment from up to down Channel 3 Color Value Color 0 15 White Open 16 31 Dark Blue 32 47 Orange 48 63 Yellow 64 79 Pink 80 95 Light Blue 96 111 Green 112 127 Magenta 128 255 Rainbow Effect Slow Fast Channel 4...

Page 5: ...otation Slow Fast 136 255 Counter Clockwise Gobo Rotation Fast Slow Channel 6 Shutter Strobe Value Feature 0 7 Blackout 8 15 Shutter Open 16 131 Strobe Slow Fast 132 139 Shutter Open 140 180 Shutter Slow Open Fast Close 181 189 Shutter Open 190 231 Shutter Fast Open Slow Close 232 239 Reset 240 247 Random Strobe 248 255 Shutter Open Channel 7 Dimmer Value 0 255 Dimmer Control 0 100 Channel 8 Built...

Page 6: ... in a case to minimize wear and tear Returns Like any complex piece of equipment designed and built by humans manufacturing errors can cause a problem If you find yourself with a fixture that isn t behaving like it should you ll need to obtain a Return Merchandise Authorization RMA Just send an email to support sdelighting com and we ll issue you an RMA Then you ll need to send the unit to us usin...

Page 7: ...A 125V Power Consumption 90W Light Source LED 1 x 60w White LED 50k Hours Optical Beam Angle 13 degrees Luminous Intensity 9 200 Lux 1m Thermal Max Operating Temp 113 degrees F 45 degrees C Control Protocol DMX 512 DMX Channels 9 Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Warranty 1 year limited warranty does not cover malfunction caused...

Reviews: