Copyright © SpectraDynamics, Inc. 2010
28
NEXT
Allows access to the next state of the state machine.
SET
Allows the setting of the four parameters describing each state of
the CS-1.
RF ON/OFF
Sets the RF relay to be on or off for this state.
FREQ
Allows entering the carrier frequency for this state, using the
Frequency Entry Menu. The frequency can be specified in
Hz, kHz or MHz and can range from 9.189631770 GHz to
9.195631770 GHz (±3 MHz with respect to the preset value
9.192631770 GHz). The frequency resolution is 10
-6
Hz.
PHAS
Allows entering the phase to be added to the RF carrier
signal for this state, using the Phase Entry Menu. The phase
is specified in degrees (deg) and must be with the interval
-360 deg to 360 deg. The resolution is 0.022 deg.
AMPL
Allows entering the amplitude of the RF carrier for this state,
using the Amplitude Entry Menu. The amplitude can be
expressed in dBm, Vrms or Vpp, always referring to 50 Ohm
characteristic impedance. The amplitude can range from
-10 dBm to +15dBm.
EXIT
Enters the new state.
+/-
Allows adding (subtract) a state to (from) the programmed
sequence:
ADD
Adds a new state,
always at the end of the existing
sequence
. By default the new state is a copy of the last state
of the sequence before the addition.
DEL
Eliminates the
last state
of the sequence.
EXIT
Return to previous menu.
SDI
State Machine Trigger Screen