7.6. Starter battery maintenance
Never place the battery close to a flame or fire
Use only insulated tools
Never use sulphuric acid or acid water to top up the electrolyte level.
Danger
As the battery is maintenance-free, just check the condition and tightness of the connections and its general cleanliness.
7.7. Cleaning the generating set
Cleaning with a water jet is not recommended.
Cleaning with high pressure cleaning equipment is forbidden.
Important
n
Remove all dust and debris from around the exhaust.
o
Clean the generating set, particularly the alternator and engine air inlets and outlets, using a cloth and brush.
p
Check the general condition of the generating set and replace any faulty parts.
8. Storing the generating set
If the generating set is not used for a long period, it must be stored in accordance with the guidelines below.
n
Using a suitable container, drain out the fuel and replace the fuel filter (
see
§ Fuel filter replacement
)
o
Start the generating set and allow it to run until it stops due to lack of fuel
.
p
With the engine still warm, change the engine oil and replace the oil filter (see
§ Renewing engine oil & Replacement of the oil
filter).
q
Clean the air filter
(see § Cleaning the air filter)
.
r
Clean the exterior of the generating set, apply an anti-rust product onto the damaged areas.
s
Cover the generating set with a drop cloth to protect it from dust and store it in a clean & dry location.
9. Troubleshooting
Problems
Probable causes
Possible solutions
Engine does not
start
Load connected to the generating set during start-up.
Disconnect the load.
Air filter (fig. A – No.14) blocked.
Clean the air filter
(see § Cleaning the air filter)
.
Fuel level too low
Fill up with fuel
(see § Filling up with fuel).
Fuel filter (fig. A – No.13) blocked.
Replace the fuel filter
(see § Replacement of the fuel
filter)
.
Oil level too low.
Check the oil level and fill up if necessary
(see. § Checking of oil level)
.
Starter battery (fig. A – No.15) defective.
Recharge or replace the starter battery.
Fuel supply blocked or leaking.
Have it checked, repaired or replaced.*
Engine stopped
Fuel level too low
Fill up with fuel
(see § Filling up with fuel).
Oil level too low.
Check the oil level and fill up if necessary
(
see. § Checking of oil level
).
No electric
current
Circuit breakers (fig. A – No. 8) not activated.
Activate the circuit breakers.
Defective devices supply lead
Change the lead
Defective electrical sockets (fig. A - No 9).
Have it checked, repaired or replaced.*
Defective alternator.
Have it checked, repaired or replaced.*
Triggering the
circuit breakers
Device connected or faulty lead.
Disconnect the device and the lead.
Overload
(see § Capacity of the generating set).
Remove the overload.
* Operation(s) to be entrusted to one of our agents.
Summary of Contents for Diesel 6000 E
Page 2: ...A O I 4 3 7 16 15 14 5 8 9 1 6 10 STOP 13 12 11 2 ...
Page 3: ...B C 1 3 2 4 5 6 1 2 3 ...
Page 4: ...D 1 3 4 5 6 2 ...
Page 15: ...1 2 3 4 Э 5 6 7 8 Х 9 10 Х 11 12 1 1 1 1 2 1 2 3 1 2 3 A B C D E F G H I J K 1 3 1 3 1 Э Э Э ...
Page 16: ...1 3 2 Э 1 3 3 Э 1 a I PE Ы II Э 60245 4 b 30 A 1 2 1 a 1 1 ...
Page 21: ...6 6 1 6 2 Э 1 1 10 1 2 50 1 6 250 1 500 7 7 1 n o 7 2 В З n A 11 A 3 o p Х q r ...
Page 23: ...7 6 7 7 n o p 8 Х n З o p З З q r s 9 У A 14 З A 13 З A 15 З A 8 A 9 ...